Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05CM03259
Review Name: SITE
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/01/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
07/05/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
07/20/2005 | JOE LINVILLE | NPPO | REVIEW | Approved | exception |
07/20/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) The previously approved site plan included 7 new parking spaces only (3 for adjacent restaurant at 5443 S. 12th ave.). Identify these spaces, show any applicable easements and note any cross access agreements. 2) Include irrigation design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, controller, low-flow bubblers or drip irrigation. 3) Provide a 6' masonry to screen the loading area from 12th Avenue. LUC Table 3.7.2-I 4) A minimum of five canopy trees are required along the east property line to meet the interior landscape border requirement. LUC 3.7.2.4 5) Decomposed granite is required between the property lines and adjacent street curbs. LUC 3.7.2.4.A.4 |
08/01/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Per LUC Sec. 3.2.6.4 Perimeter Yard "DD", the building setback from the east lot line is based on 1 ½ times the building wall height. Proposed building height is 15'7" and shall require a setback of 23.375 feet. The plan currently proposes 14 foot setback from the east lot line. (D.S. 2-02.2.1.A.7) 2. Label and dimension the building setback from the edge of travel lane along Oregon Street. Since the site is adjacent to a MS&R (12th Ave), all other streets bounding the project shall be considered a "developing area" for setback purposes. A minimum 21 foot setback shall be provided from the nearest edge of travel lane to the building wall. (LUC 3.2.6.5.B.1) 3. Indicate if porch area will have a cover or canopy. If so, indicate the location of posts and edge of overhang on the drawing. Porch cover may not overhang onto vehicular use area/parking spaces. (D.S. 2-02.2.1.A.6) 4. Will the "no parking" area labeled on the site plan be used for something else? If so, indicate on plan. 5. Label the handicap parking space on the plan. (D.S. 2-02.2.1.A.8) 6. Existing sign is located in the vehicle overhang area. Relocate sign or indciate how the sign will not obstruct vehicle parking. (D.S. 2-02.2.1.A.13) 7. If applicable, all existing and proposed easements must be shown on the plan including width, type, and recording docket and page reference and whether they are private or public. (D.S. 2-02.2.1.A.20) 8. Label and dimension future curb location along 12th Avenue. Face of future curb shall be located 11 feet from the future right-f-way line. (D.S. 2-02.2.1.A.21) 9. Add a general note, which states the proposed uses as they are listed under the C-2 zone in the LUC. Include the land use class, development designator, and "subject to" section. (D.S. 2-02.2.1.A.31) 10. Revise proposed F.A.R. to be listed as .26. (D.S. 2-02.2.2.A.3) 11. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
08/02/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Denied | Label the handicap parking space on the plan. (D.S. 2-02.2.1.A.8) |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
08/02/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
08/02/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |