Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05CM03161
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 09/01/2005 | JOE LINVILLE | NPPO | REVIEW | Approved | EXCEPTION |
| 09/01/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) The loading area is required to be screened from the street per LUC table 3.7.2-I. Note heights of and materials used for screening elements on the site and landscape plans. 2) The refuse storage area is required to be screened from the street and adjacent properties per LUC table 3.7.2-I. Note heights of and materials used for screening elements on the site and landscape plans. |
| 09/14/2005 | MICHAEL ST. PAUL | ZONING HC SITE | REVIEW | Approved | |
| 09/14/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 09/23/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Bruce Wilson Landmark Engineering, Inc. 3845 N. Bussiness Center Drive Tucson, Arizona 85718 SUBJECT: Sonic Restaurant, 2400 N. Pantano Road Site Plan T05CM03161 (First Review) T13S, R15E, Section 33 RESUBMITTAL REQUIRED: Site Plan. The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 3. Please provide property description per D.S. 2-02.2.1.3. 4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. 5. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. 6. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 7. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 8. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 9. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 10. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 11. Show Site plan number (T05CM03161) on all sheets per D.S. 2-02.2.1.29. 12. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Show a detail on the refuse enclosure on the plans. 13. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 14. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 15. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice. 16. List the consulting engineer and the owner/developer on the plans with the pertinent information. 17. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Drainage Statement: 1. The DS has been accepted for SP purposes only. 2. Show the project address or administration address on the cover sheet of the DS. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/2400 N. Pantano Rd Site |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/26/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 09/26/2005 | SUE REEVES | REJECT SHELF | Completed |