Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM02891
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2005 | GERRY KOZIOL | WWM | REVIEW | Denied | Left message; need perc and design 6/30/05 |
| 07/21/2005 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T05CM02891 7/22/05 2590 N. WOODLAND DR. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. PLEASE INDICATE THE LOCATION OF THE WATER WELL OR WATER METER. STRUCTURAL PLANS: 1. PLEASE CHECK THE AVAILABILITY OF TJI's 150 AND 250 SERIES I-JOISTS. I'VE INCLUDED THEIR LATEST, I HOPE, 8 ½" X 11" SPEC SHEET WITH SERIES AND SPANS. CALL ME IF IT DOESN'T MAKE IT TO YOU. 2. ROOF PLAN / 8 ; WITH THIS VENT ARRANGEMENT WITH I-JOISTS, HOW DOES THE VENTILATION TRAVEL LATERALLY? SECTIONS - DETAILS - MISC. NOTES: 1. 7, 9, 10 / 8 ; PLEASE SPECIFY THE JOIST HANGERS. 2. PLEASE ADD A NOTE THAT SAG RESISTANT GYPSUM BOARD IS REQUIRED WHERE ½" IS HUNG ON A CEILING THAT IS FRAMED AT 24" O.C. SEE TABLE R702.3.5 FOOTNOTE D . 4. PLEASE PROVIDE A DETAIL OF THE CONNECTION AT THE BOTTOM OF THE VIGA POSTS TO THE CONCRETE. IF EPOXY IS USED TO SET AN EMBEDMENT AS IN A SIMPSON PBV, A SPECIAL INSPECTION IS REQUIRED. PLUMBING PLANS: 1. NOTE AND SPECIFY ALL PIPING MATERIALS. 2. PLUMBING NOTE #8 / 9 ; PLEASE CLARIFY THE 150 PSI. IS THIS FROM A WELL? IS THIS THE RATING OF THE WATER PIPE? A PRESSURE REDUCER IS REQUIRED FOR PRESSURES OVER 80 PSI. IF ON A WATER METER, PLEASE SPECIFY THE SIZE OF THE WATER METER. 3. PLEASE SPECIFY THE MAXIMUM LENGTH OF THE WATER DISTRIBUTION SYSTEM? 4. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. 5. HOW WILL THE KITCHEN SINK BE VENTED? IF AN AIR ADMITTANCE VALVE IS TO BE USED, PLEASE NOTE. IF AN ISLAND VENT , CHICAGO LOOP, IS TO BE USED, PLEASE PROVIDE A DETAIL. 6. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. GENERAL DESCRIPTION. ELECTRICAL PLAN: 1. PLEASE PROVIDE A RECEPTACLE ON THE WALL BEHIND THE DISH WASHER. SEE E3801.2.2 ITEM 1 . 2. PLEASE PROVIDE ARC FAULT PROTECTION FOR THE BED ROOM RECEPTACLES. SEE E3802.11 . IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 PLEASE UPDATE THE CODE REFERENCES IN THE NOTES FROM 2000 TO 2003 IRC. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/27/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |