Permit Number: T05CM02696
Parcel: 107110010

Address:
3175 N 1ST AV

Review Status: Completed

Review Details: REVISION - SITE

Permit Number - T05CM02696
Review Name: REVISION - SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/08/2006 JIM EGAN FIRE REVIEW Approved
02/13/2006 PETER MCLAUGHLIN NPPO REVIEW Passed
02/13/2006 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
02/13/2006 PETER MCLAUGHLIN ZONING HC SITE REVIEW Approved
02/13/2006 PATRICIA GEHLEN ZONING REVIEW Denied 1. The number of spaces required for any non-residential development located on a designated MS&R street may be reduced only up to twenty (20) percent in conformance with calculations in LUC 2.8.3.7. The proposed MS&R reduction from 8 parking spaces to 6 results in a 25 percent reduction. Revise plan drawing and parking calculations to show no fewer than seven (7) total parking spaces required and provided.
LUC 3.3.8.2

2. In order to allow the pole mounted sign to remain within the future right-of-way a note must be placed on the plan indicating that the sign will be removed at time of intersection widening at no expense to the City of Tucson.

3. The minimum required text size for microfilming/archiving purposes is 12 point (12"). Revise the scale and the wording in the title block which read "Addition and Tenant Improvement Project For:" on sheet A-2, as well as all of the text in the site plan drawing and location map on sheet A-1, to meet this minimum archiving standard.

4. Dimension the MS&R setback from back of Fort Lowell Road's future curb to the new canopy (keynote 10) at its closest point. The setback requirement is the greater of 21 feet or the height. The canopy scales to be only 16 feet from the back of future curb. Specify the height of the new canopy and dimension its distance from back of future curb. Also, the minimum required two-way PAAL width is 24 feet and the canopy may not extend into the 24-foot PAAL as shown on the plan. A minimum 1-foot setback is required from the PAAL to the closest part of the overhang structure. Revise plan.
LUC 3.2.6.5
LUC Table 3.3.7-I
DS 3-05.2.2.B.1

5. Revise site plan on sheet A-2 to indicate the adjacent zoning (C-2) immediately to the west of the site (near the top of the page).
DS 2-02.2.1.A.28

6. A cross access agreement is required with the property to the south. Provide a copy of the recorded cross access agreement and add a note stating the docket and page of its recordation.
02/23/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: February 23, 2006
ACTIVITY NUMBER: T05CM02696-R
PROJECT NAME: Buckeye Check Cash
PROJECT ADDRESS: 3175 North 1st Avenue
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

1. The solid waste vehicle can not safely maneuver into the current location of the trash enclosure because of the shown awning that is attached to the structure. The solid waste vehicle has potential of hitting the awning. Revise the plan to relocate the solid waste enclosure or to show the awning extend into the PAAL.

2. The new sidewalk located on the west side of the property must be handicap accessible for accessibility within the ROW. Currently vertical curb is proposed within the ROW which restricts accessibility. Depress the curb and revise the sidewalk in ROW to comply with ADA accessibility.

3. A cross access agreement is required with the property to the south. Provide a copy of the recorded cross access agreement and add a note stating the docket and page of its recordation.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/28/2006 JMORALE1 OUT TO CUSTOMER Completed
02/28/2006 SUE REEVES REJECT SHELF Completed