Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T05CM02543
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/15/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Additional tree(s) is required for north parking area. 2. Provide the correct Activity /Case number on the application for exception for approval. |
| 09/15/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Jeff Stanley, PE SUBJECT: 1790 West Saguaro Drive Addition Resubmittal Site Review REVIEWER: Elizabeth Eberbach DATE: September 15, 2005 ACTIVITY NUMBERS: T05CM02543 SUMMARY: Engineering Division of Development Services Department has received and reviewed the plan submittal and does not recommend approval at this time. Address the following comment. SITE PLAN COMMENT: 1) Tucson Code Sec.26-11: Submit a Floodplain Use Permit Application for the project. For resubmittal provide three copies of the revised Site Plan sheets, a Floodplain Use Permit Application, and . Due to the closed City of Tucson Landfill located at this site; development on or within 100 feet of a landfill requires Environmental Services review and the project shall comply with any Environmental Services requirements per Tucson Code Sec.29-23.A.1; provide documentation from ES that project has been reviewed. If the project is approvable, the site plan may be approved at the counter after the Floodplain Use Permit application is processed. If you have any questions, I can be reached at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 09/15/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Provide the correct Activity /Case number on the application for exception for approval. |
| 09/16/2005 | TERRY STEVENS | ZONING HC SITE | REVIEW | Approved | |
| 09/16/2005 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 09/21/2005 | JMORALE1 | LANDFILL | REVIEW | Needs Review |