Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T05CM02468
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/07/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Approved | |
| 06/08/2005 | GERRY KOZIOL | WWM | REVIEW | Denied | partial count of plumbing fixtures needs wastewater 8th floor credit evaluation |
| 06/14/2005 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 06/14/2005 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 06/29/2005 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T05CM02468 6/30/05 2836 E. 1st ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLANS: 1. HOW DOES THE 3036 CASEMENT ADJACENT THE WATER HEATER DOOR COMPLY WITH R308.1 ? IS SAFETY GLASS REQUIRED? ELEVATIONS: 1. INDICATE ALL MATERIALS USED; STUCCO, CONCRETE BLOCK, GLASS BLOCK, ROOFING SYSTEMS, SIDING, VENEERS, ETC. 2. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4. SECTIONS - DETAILS - MISC. NOTES: 1. B / 3 ; PLEASE DESCRIBE THE ROOF DECKING MATERIAL AND THE ROOFING MATERIAL. 2. B / 3 ; ANCHOR BOLTS IN MASONRY WALLS REQUIRE 4" MINIMUM EMBEDMENT. SEE FIGURE R606.10(3). 3. B / 3 ; ANCHOR BOLTS IN CONCRETE REQUIRE 7" MINIMUM EMBEDMENT. SEE R403.1.6 . 4. TYPICAL WALL / 5 ; PLEASE PROVIDE THE FOOTING'S THICKNESS. 5. TYPICAL WALL / 5 ; PLEASE PROVIDE THE DUROWALL @ 16" O.C. SEE R606.11.2.1.3 . 6. ROOF PLAN / 5 ; SHOULD THE SECTION LINES REFERENCE SHEET 5? 7. SECTION C-C / 5 ; SHOULD THE KNEE BRACE DETAIL REFER TO SHEET 5? 8. KNEE BRACE DETAIL A / 5 ; DESCRIBE THE DECK AND ROOFING. 9. KNEE BRACE DETAIL A / 5 ; PLEASE PROVIDE CONNECTIONS FOR THE RAFTER / BEAM, BEAM / KNEE, AND KNEE / STUD. 10. PLEASE PROVIDE A SECOND SET OF TRUSS DATA SHEETS. PLUMBING PLANS: 1. PLEASE ELIMINATE THE FLAT VENTS FROM THE RISER DIAGRAM. 2. EXISTING WATER SERVICE / 7 ; LAVATORIES ARE 1 F.U. SEE UPC TABLE 6-3 3. PLEASE SPECIFY A 1" WATER METER . SEE UPC TABLE 6-4 4. THE WATER SERVICE CALCULATIONS CALL FOR A 1 ½" WATER SERVICE LINE BUT THE PLAN SPECIFIES 1¼" LINE. 5. PLEASE USE 1000 BTUs PER CUBIC FOOT OF GAS IN THE GAS CALCULATIONS. ELECTRICAL PLANS: 1. LIGHT FIXTURES OVER TUBS AND SHOWERS ARE REQUIRED TO BE LISTED AS APPROVED FOR USE IN WET AREAS. 2. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 3. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. ADDITIONAL PLAN CHECK COMMENTS 1. NOTE ON PLANS: GLASS IN HAZARDOUS AREAS, ALL GLASS WITHIN 18" OF THE FLOOR AND WINDOWS WITHIN A 24" ARC OF EITHER VERTICAL EDGE OF A DOOR SHALL BE SAFETY GLASS. UBC SEC 2406. 2. PROVIDE COMPLETE PLANS AND CAL'CS FOR POST TENSION WALL SYSTEM BY STRUCTURAL ENGINEER REGISTERED IN THE STATE OF ARIZONA. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/06/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 07/06/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |