Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM02396
Parcel: 11308171A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T05CM02396
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/08/2005 GERRY KOZIOL WWM REVIEW Denied NEEDS 8TH FLOOR REVIEW. property split crossing adjacant property. does not front public sewer. need recorded easements. may need joint use agreement. Site plan shows ingress-egress & utility easement sewer on other side of front lot.
08/12/2005 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T05CM02396

8/12/05 1029 E. BLANTON DR. 2nd REVIEW

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

STRUCTURAL PLANS:

1. TRUSSES "T4" AND "T5" DON'T APPEAR TO FIT.

SECTIONS - DETAILS - MISC. NOTES:

1. 2 / 7 ; RETAINING WALLS OVER 4' TALL, MEASURED FROM THE BOTTOM OF THE FOOTING, REQUIRE AN ENGINEER'S DESIGN. THE STEM WALL ( RETAINING WALL) APPEARS TO BE OVER 4' TALL, MEASURED FROM THE BOTTOM OF THE FOOTING. WOULD YOU CONSIDER A RESTRAINING WALL?

PLUMBING PLANS:

1. THE WATER DISTRIBUTION APPEARS TO BE UNDERSIZED. A ¾" WATER METER WITH A 1" WATER LINE PROVIDES ONLY 28 f.u. ACCORDING TO TABLE 6-4. INTERPOLATION BETWEEN 100' AND 15O' TO 147' ONLY PROVIDES LESS THAN 1 f.u. MORE. ALSO, ¾" LINE ONLY PROVIDES 14 f.u. ; PLEASE CHECK THE INTERIOR PIPING.

2. BOTH OF THE MASTER BATH LAVATORIES ARE ON ONE TRAP ARM. PLEASE SEE U.P.C. 1001.1


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
08/18/2005 JMORALE1 OUT TO CUSTOMER Completed
08/18/2005 SUE REEVES REJECT SHELF Completed