Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM02189
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/14/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 07/18/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | Conforming structure in an AE Zone. |
| 08/03/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 08/15/2005 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T05CM02189-1.. 40 W FORT LOWELL ROAD .. DGL .. 8/15/05 .. 2ND REVIEW .. S1. See prior comment #S2, provide requested drawings. (S2. Provide complete floor plan on drawings for this tenant space as it has been expanded to include 20 W Fort Lowell Rd and 40 W Fort Lowell Rd, show all rooms and their uses.) S2. See prior comment #S3, clarify designation of fire wall listing on drawings. (S3. Please explain fire wall designation for interior masonry wall, as this wall is indicated as a shear wall only on original drawings for this structure. If it has been modified to become a fire wall, please clarify type of fire wall per IBC Section 7 and provide details and fire listing on the drawings.) S3. See prior comment # S4, provide Structural Engineer's seal and signature on drawings with structural details for folding partition. (S4. Provide structural design and calculations for folding partition support structure by an Arizona Registered Structural Engineer.) S4. See prior comment #S5, clarify exiting, as requested. (S5. Clarify exiting from entire tenant space, including classrooms.) S5. See prior comment #S6, provide requested information, on drawings. (S6. Clarify that minimum number of required plumbing facilities are provided per IBC Table 2902.1 and men's accessible toilet facility is/are provided and designated on floor plan, per IBC Section 29.) S6. Provide requested information, on drawings.(S7. Clarify use of room #104.) S7. See prior comment #S8, if site and buildings on site conform to Accessibility requirements of the 2003 ed of the International Building Code Chapters 11 and 34 and ANSI A117.1-2003 ed and you wish to note this on the drawings, please do so. (S8. Show where 20% of this alteration is spent on accessibility per IBC Section 3409.) Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/08/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |