Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM02100
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/16/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/21/2005 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS for Activity # T05CM02100 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All corrections and revisions shall be made on the original tracings and two new sets of drawings shall be returned along with all redline prints. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. FOUNDATION PLANS: 1. Show compliance with termite treatment specified by R320. FLOOR PLANS: 1. Provide the location of tempered safety glass per R308.4. including the computer room casement window. 2. Clarify the accessible entrance statement on sheet #2 showing compliance with not less than one 3-0 x 6-8 door R311.4.2. 3. Note that bathtub and shower enclosures shall be finished with a nonabsorbent surface, or a listed enclosure, to a height of 6' above the drain per R307.2. and R702.4. All glass enclosures shall be tempered R308.4. 4. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture) and has a clear space in front not less than 21" per figure R307.2. STRUCTURAL PLANS: 1. Detail #2 may require a column to carry the glu-lam ridge beam. This 5-1/8" x 11-1/8" beam appears to be undersized and may not be a standard size. Verify and specify the manufacturer. 2. Complete section detail #6 showing porch rafter. 3. Complete section detail #8 showing porch rafter. 4. Complete section detail #12 showing upper window header and support, or detail the wall framing. 5. Specify and locate foundation hold-downs for the alternate brace walls on each side of the studio window (and west wall across from studio 6. door) per R602.10.6. 6. Detail gable end bracing and it's connections to structure. ELEVATIONS: 1. For thin-coat stucco systems over foam board, note and specify the ICBO evaluation report number, system name and manufacturer, note and specify the vapor barrier. PLUMBING PLANS: 1. Correct the plumbing fixture schedule showing unit values prescribed by the 1994 UPC table 6-3. 2. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute. 3. Provide pressure and temperature relief valve at water heater. T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down. 4. Hose bibs require backflow preventers per UPC 603. MECHANICAL PLANS: 1. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24. 2. Show bathroom exhaust fan CFM rates per R303.3 and M1506. ELECTRICAL PLANS: 1. Receptacle outlets shall be provided at each kitchen counter space wider than 12", and shall be installed so that no point along the wall line is more than 24" from a receptacle outlet, per E3801.4.1. 2. Note that two or more 2O AMP small appliance circuits shall be provided to serve all receptacles outlets in the kitchen, breakfast room and dining room. Such circuits shall have no other outlets, per E3603.2 and E3801.3 through E3801.4.5. 3. Provide a note indicating only approved outlet boxes shall be used for ceiling fans, per E4001.6. If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/28/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 06/28/2005 | SUE REEVES | REJECT SHELF | Completed |