| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/26/2005 | TERRY STEVENS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Terry Stevens FOR: David Rivera Senior Planner Principal Planner PROJECT:T05CM02094 2132 E Balsam Cir. Addition: Bedroom/Computer room/Dining room Site Plan Transmittal date: 1st Review 5/27/05 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Provide the height of the exterior walls of the new building addition or structure measured from the average grade to the highest point under the roof to the top of the parapet. South:_______________feet high West:_______________feet high As per DS2-02.6 2. As per Luc Sec. 6.2.2 Definitions B------- Bedroom. The term bedroom shall include all of the following. B. Any enclosed room which has a minimum area of sixty (60) square feet and has an accessible opening to the exterior of the building in compliance with the International Building Code (IBC), whether termed a studio, family room, study, den, bonus room, or any other name, except for a living room, dining room, kitchen, and bathrooms. This proposed addition will bring the structure to a total of 5 bedrooms(considering the family room as a dining room) as per the above definition. As per LUC Sec. 3.5.7.1.G,and.H G. For any new single family dwelling in the R-1 zone with five (5) bedrooms, three (3) parking spaces are required. For every bedroom over five (5), one additional space is required for each bedroom. H. For all single family dwellings in the R-1 zone with five (5) or more bedrooms, and for all lots containing two (2) or more single family dwellings, with the second dwelling having more than one bedroom, all parking and maneuvering must be located on-site, either in a side or rear perimeter yard. The vehicular use area must be improved, which includes surfacing, striping, and provision of barriers, in conformance with Development Standard 3-05.0. Parking spaces may not be located in a vehicular use area in any front street perimeter yard. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5608 ext. 2000. |
| 06/09/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/14/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |