Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T05CM02080
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/07/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/27/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T05cm02080 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. 3. Notes are illegible on Floor, Foundation, Roof Framing and Plumbing plans. Provide readable notes. Floor Plan 1. Note 14, page2 - 1024 sq. in. rather than 900. 2. Note and specify that shower enclosures shall have a minimum finished interior area of 1,024 square inches and shall be capable of encompassing a minimum 30" circle per 1994 UPC SEC. 410.0. All glass enclosures shall be tempered. 3. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2. 4. Provide tempered glass at windows adjacent front door within 2' of doorjamb. 5. Note 1, page2 notes frame wall while other locations and details show CMU walls. Structural Plan 1. Post footing at SW corner of south porch is dimensioned at 36" square on foundation plan but called out on detail 6/6 as 16" square. Clarify. 2. Column discrepancy - CMU or wood posts - Floor plan notes 16" square CMU columns while foundation detail 6/6 notes wood posts. Clarify. Provide CMU column cross section with footing and include beam to column connection. OR If wood post are used, provide post to beam connection and dimension 6" from grade to post on detail 6/6. 3. Detail truss to beam connection. 4. Truss end connection - Provide cross bracing at gable end. Also, should this be detail 11/6? 5. 1/6 and 2/6 - Note pressure treated lumber on slab. 6. Provide detail 12/6 - Truss to Girder connection. 7. Detail Girder truss to posts or columns. 8. Note interior finishes on all pertinent details. 9. Note and dimension that the fireplace chimney must terminate a minimum of 2' above any point of roof within 10' measured horizontally and not less than 3' above the point where the chimney passes through the roof, per R1001.6. 10. Note and specify a complete roofing system: Roofing type, grade of materials and method of installation per R905. 11. Note and specify all roof slopes appropriate to material. (Minimum allowable roof slope is ΒΌ" per foot per R905.11.1). 12. Porch beams are inadequate for spans and tributary widths with tile roofs. Resize. 13. When using 1/2" sheetrock on ceiling with rafters or trusses spaces at 24"o/c, use the sag resistant type per table R702.3.5. Specify. Plumbing, Mechanical and Electrical Plans 1. Specify 2" vent from hall WC to 3" VTR. 2. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code. 3. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24. 4. Gas appliances shall comply with ARIZONA STATE PLUMBING CODE combustion air requirements or Chapter 17, 2003 IRC. Detail how you will comply. Water heater. 5. Note on plans: Electrical work shall comply wit chapters 33-42 2003 IRC. 6. Where ceiling fans are shown on the plans, provide a note indicating only approved outlet boxes shall be used, per E4001.6. 7. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11. 8. Provide arc-fault protection for all bedrooms per E3802.11. 9. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. MODEL ENERGY CODE: 1. Table N1102.1 is based on the home having a 15% or less glazing to wall ratio. Show this calculation. Also 2100 HDD governs. All glass must be low 'E'. Outdoor Lighting Code 1. Show compliance with City of Tucson Outdoor Lighting Code (www.ci.tucson.az.us/dsd/Codes___Ordinances/Tucson_Lighting_Code.pdf). 2. Provide cut sheets of chosen lights. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes. |