Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM01946
Parcel: 11519034A

Address:
1805 W GRANT RD

Review Status: Completed

Review Details: COMMERCIAL NEW

Permit Number - T05CM01946
Review Name: COMMERCIAL NEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/25/2005 JIM EGAN FIRE REVIEW Approved
06/09/2005 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens FOR: David Rivera
Senior Planner Principal Planner

PROJECT:T05OT01110 & T05CM01946
1805 W. Grant Rd.
Storage Yard/Light Poles

Transmittal date: 1st Review 6/13/05

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please indicate clearly what type of equipment is going to be stored on this site. I am unable to determine the use group proposed for the property based on the information provided. The following review comments are based upon a commercial storage use.

2. The electrical plan indicates power for the light poles is being provided from the property to the west. This site must be considered a stand alone property or the increase in lot area will cause the entire property to the west to be brought up to full code compliance as well.

3. Clearly indicate that there is no access from the proposed site to the property to the west.

4. As per DS 2-02.2.1.6 Indicate the area to be used for the commercial storage along with the square footage of the storage area.

5. As per DS 2-02.2.1.7. Indicate the required and proposed zoning setbacks.

6. As per DS 2-02.2.1.8. Indicate the required off street parking, including fully dimensioned layout, location, parking spaces, size and number, and typical parking space details for both handicapped and standard spaces, together with access thereto.

7. As per DS 2-02.2.1.9 Off-street bicycle parking, including materials for lighting, paving, and
security; fully dimensioned layout; location; specific type of rack and the
number of bicycles it supports; and the location and type of directional
signage.

8. As per DS 2-02.2.1.10 Existing and future sight visibility triangles.

9. As per DS 2-02.2.1.11 Points of egress and ingress including locations and width of driveways
and parking area access lanes (PAALs).

10. As per DS 2-02.2.1.12 Vehicular, bicycle, pedestrian, and handicapped circulation clearly
identified.

11. As per DS 2-02.2.1.13 Location, type, size, and height of existing and proposed signage. If applies.

12. As per DS 2-02.2.1. 14 Fully-dimensioned loading space(s) and maneuvering area(s).

13. As per DS 2-02.2.1. 21 Dimensions from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines.

14. As per DS 2-02.2.2.A. The following calculations are required on the site plan, including the methodology. If there is not enough space on the site plan to include these calculations, another plan sheet is used.
1. Gross and net lot area.
2. Floor area for each building.
3. Percentage and area in square feet of building and accessory building
coverage.
4. Vehicular and bicycle parking spaces required and provided, including
handicapped.
5. Number of loading spaces required and provided.
6. Percentage of building or lot area expansion. If the building(s) or lot area
have been previously expanded, those calculations shall be included.

15. As per a discussion with Wayne Bogdan of Zoning Enforcement this project will require an interpretation from the Zoning Administrator as to whether it is an expansion of the property to the west or a stand alone use, as well as, if it is a stand alone use will a building be required. Please submit a letter along with plans to the Zoning Administrator for his interpretation. The next resubmittal must include a copy of the letter with the Zoning Administrator's determination.

16. Depending on what is resubmitted and what the Zoning Administrator's determination is, further comments may be forth coming.



If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5608 ext. 2000.
06/17/2005 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Minimum font size is 1/8". Please enlarge as appropriate.
2. Please demonstrate compliance with the Tucson Lighting Code, http://www.tucsonaz.gov/dsd/Codes___Ordinances/Tucson_Lighting_Code.pdf.
3. The 20' of copper coil at the base of each pole shall be #4 per NEC 250.52 (A) (3).
4. Since the pole is 32' high, it will need structural calculations for both pole and foundation, sealed by a Registered Structural Engineer. Coordinate with Building/Structural plans Examiner.
5. Gate is on a single pole CB at the Panel Schedule, but a 2P Disconnect in the field. Pls clarify.
6. In the Load Summary, please fill in the KW reading for the 12 month high.
7. Provide the capacity of the existing gutter and size of service entrance conductors.
8. Provide Available Fault Current at the service.
9. Provide fault calculations for AFC at the new Panel.
06/22/2005 LOREN MAKUS ENGINEERING REVIEW Denied Site plan must be approved before the light poles can be approved.
06/22/2005 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied S1. PROVIDE DESIGN OF LIGHT POLE FOOTING BY See prior comments as revised below.
S1. STRUCTURAL ENGINEER.Provide seal and signature on this set of drawings with foundation details, structural calculations required.
S2. LOCATE LIGHT POLES BY DIMENSION FROM TWO ADJACENT PROPERTY LINES.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/28/2005 JMORALE1 OUT TO CUSTOMER Completed
06/28/2005 SUE REEVES REJECT SHELF Completed