Permit Review Detail
Review Status: Completed
Review Details: CELL TOWER/ANTENNAS
Permit Number - T05CM01926
Review Name: CELL TOWER/ANTENNAS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2005 | GLENN MOYER | PLANNING-CITY HALL | REVIEW | Approv-Cond | Building permit may not be issued until end of appeal period, 6/3/05. |
| 05/14/2005 | BLANCA ESPINO | ENGINEERING | REVIEW | Approved | |
| 05/20/2005 | JAY HOGAN | OPERATIONS | REVIEW | Passed | |
| 05/26/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov IF YOU CARE TO DISCUSS. 1. Exterior lighting shall comply with the current Lighting Ordinance, http://www.tucsonaz.gov/dsd/Codes___Ordinances/Tucson_Lighting_Code.pdf. 2. All exterior lighting shall have a source efficiency of at least 45 lumens per watt. Please demonstrate that the flagpole lighting and the area lighting are in compliance. 3. If the SSC Cabinet is a listed piece of equipment, please state so on the plans. Otherwise, provide conductor sizes and insulation types for all branch circuits. 4. Specify conduit and conductor size and type for flagpole lighting conduit. 5. On Sheet E7, note 9B refers to "Note 10A above". Could this mean "Note 9A above?" 6. This is not a Code issue for the City of Tucson, but Tucson Electric Power Company may not provide a single-phase 208V service. Suggest a back-check. 7. Panel A is specified as a service entrance cabinet. Please note that since the service disconnect and therefore Main Bonding Jumper are located in the meter cabinet on the line side of this panel, it would not be Code-compliant to allow the N-G bond to take place at this panel as well. |
| 06/01/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | Site plan approval required prior to structural approval. |
| 06/01/2005 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T05CM01926 .. 510 W. LIMBERLOST DRIVE .. 1ST REVIEW .. DGL .. 6/1/05 .. S1. Provide site plan showing entire site with property lines and dimensionally locate monopole, new fencing, patio walls and equipment from two adjacent property lines. S2. Show conformance with 2003 International Building Code : 1. In structural calculations by using up-to-date Referenced Standards 1. ASCE 7-02 versus ASCE 7-98 referenced in calculations 1. S C I Foundation Design for Flagpole 2. Mactec Soils Report reference to 2000 IBC, provide letter from Soils Engineer-of -Record. S3. Address the requirement for engineered fill on the drawings per the Soils Report. S4. Provide Inspection Program, as required by 1997 Uniform Administrative Code Section 302.5. S5. Special inspection for : 1. Caisson. 2. Site preparation. 3. Bolts-in-concrete. 4. Reinforcing. 5. Concrete. 6. Masonry. 7. High-strength bolting. S6. Submit two sets of shop drawings and calculations, stamped and signed by an Arizona Registered engineer, shop drawings shall be reviewed by and bear the approval of the Engineer or Architect of Record prior to submission to the City of Tucson , Development Services Department for approval prior to erection for : 1. Radomes. 2. Spacer. 3. EMS antenna mounts. 4. 12" gold ball. 5. Flag truck. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/10/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |