Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM01924
Parcel: 113031840

Review Status: Completed

Review Details: OTHER

Permit Number - T05CM01924
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2005 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS for Activity # T05CM01924

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

All dimensions and notes shall be consistent on each plan or elevation.
1. Section A on sheet #3 relates to detail B on sheet #7.
2. Correct note #7 on sheet #4 showing compliance with 2003 IRC.
3. Correct the riser diagram note on sheet #10 showing compliance with 2003 IRC.

FOUNDATION PLANS:

1. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per table R401.4.1 if this does not conflict with the designer / homebuilder's awareness of the soil and conditions of the site. If soil testing has been done, a copy of the soils report shall be submitted with the construction plans, and the foundation design shall reflect the soils reports recommendations.
2. Provide specifications for the fireplace and detail any necessary footings.
3. All slabs and pads, including landings at all doors, shall be shown and their thickness specified R311.4.3.
4. Locate and specify all anchor-bolt spacing on the foundation plan. Minimum ½" diameter with 7" embedment into concrete or masonry. Maximum spacing 6' O.C. and within 12" of each end of sill plate per R403.1.6.
5. Show compliance with termite treatment specified by R320.
6. Note that grade away from foundations shall comply with R401.3.

FLOOR PLANS:

1. Show interior wall covering and fastening R702.
2. Note that bathtub and shower enclosures shall be finished with a nonabsorbent surface, or a listed enclosure, to a height of 6' above the drain per R307.2. and R702.4. All glass enclosures shall be tempered R308.4.
3. Show that each water closet is located in a clear space not less than 30" wide (centered 15" from finished wall or fixture) and has a clear space in front not less than 21" per figure R307.2.
4. Show fireplace location, hearth size and materials, per R1003.10 or R1004.2. For factory built or zero clearance fireplaces, provide cut sheets, make, model number and the approval number of the approved testing agency (IE: ICBO #), per R1002 (specifications not required to be on plan). Factory built fireplaces shall comply with UL-127. For masonry fireplaces, show cross-section, per R1003.

STRUCTURAL PLANS:

1. Provide manufacturer's calculations and data for pre-fabricated trusses, or note the requirement for deferred submittal at installation. The engineer of record shall review and "SHOP DRAWING" stamp approval on truss calculations
2. Detail gable end bracing and it's connections to structure.

ELEVATIONS:

1. Note and specify a complete roofing system: Roofing type, grade of materials and method of installation per R905.
2. Clarify foam insulation compliance with R314 including where the top edges of exterior walls enter into the attic space R314.2.3.

SECTIONS - DETAILS - MISC. NOTES:

1. All wood-framing members that rest on concrete shall be protected against decay R319.1.
2. Show ceiling insulation with baffles and venting per R806.3.

PLUMBING PLANS:

1. The City of Tucson has adopted the 1994 Uniform Plumbing Code with state amendments (ARIZONA STATE PLUMBING CODE). All plans must reference this code.
2. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute.
3. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type.

MECHANICAL PLANS:

1. Note on plans: Mechanical shall comply with 2003 IRC chapters 13 - 24.
2. Show dryer vent size and location M1501.
3. Show exhaust fan air flow rate in compliance with M1506.

ELECTRICAL PLANS:

1. Show the circuit number for all laundry closet outlets, bathroom and kitchen lights.
2. Show the switch location for the laundry closet light and kitchen disposal if installed.
3. Circuit #19 may not serve both the refrigerator and ceiling fans or lights.
4. Bathroom outlets shall be on a separate 20 AMP circuit with no other (outdoor) outlets, per E3603.4.
5. Show compliance with City of Tucson Outdoor Lighting Code (www.ci.tucson.az.us/dsd/Codes___Ordinances/Tucson_Lighting_Code.pdf).
6. Provide cut sheets of chosen lights.

MODEL ENERGY CODE:

1. Show that MEC calculations meet the pass/fail requirements.
2. Show the low "E" ratings for the windows and doors related to energy calculations.

If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/27/2005 KMEDINA1 OUT TO CUSTOMER Completed