Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM01826
Parcel: 126150990

Address:
4350 E 13TH CI

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T05CM01826
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/27/2005 GERRY KOZIOL WWM REVIEW Approved Need plumbing drawing. Needs 8th floor WW credit review.
05/31/2005 NEAL SAUNDERS BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T05cm01826

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Site Plan

1. Specify distance from tool shed to property line on south side of property.
2. Indicate the location of gas line on the property, and where they enter the building.

Floor Plan

1. All exterior doors require a landing or floor at the exterior. Landings must be at least as wide as the doors they serve and 36" in the direction of travel per R311.4.3. French doors at new family room and exterior door from new bedroom.
2. Note and specify that shower enclosures shall have a minimum finished interior area of 1,024 square inches and shall be capable of encompassing a minimum 30" circle per 1994 UPC SEC. 410.0. All glass enclosures shall be tempered.
3. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2.
4. Locate and identify brace wall types and locations along with the appropriate nailing schedule.
5. Provide tempered glass in all windows that are within 2' of doorjamb per R308.4 (#6).

Foundation Plan

1. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 PSF is being used per table R401.4.1.

Structural Plan

1. Detail 2/8 notes R-19 in ceiling in 2x4 joists while MEC and section 1/9 note R-30 and TJI rafters. Clarify.
2. Specify TJI type.
3. Detail TJI to ledger and ledger to wall connection on bearing walls.
4. Detail non-bearing condition for roof joists. Roof diaphragm must be complete.
5. 4x8 over entrance to new walk-in closet is inadequate for span of 6.25' and 21.5' of tributary width. Resize or justify.
6. 4x12 over entrance to new family room is inadequate for span of 11.25' and 20' of tributary width. Resize or justify. Clarify beam connection and support at south end of opening.
7. Provide headers for all openings.
8. Detail pony walls that make up parapet of new addition that are built over new openings (above beams) and existing walls. Include connections to new beams or existing walls as well as ledger connections.
9. Clarify construction of walls at east and north end of house (exterior walls of new bathroom and walk-in closet). Specify whether these walls are completely new or a remodel of existing. Provide pertinent details for wall to foundation and wall to roof connections. Also walls must be braced. Provide Braced wall panels per R602.10. Are footing existing and adequate? Specify.
10. Show all crickets on roof plan.
11. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply. OR fill I-joist space with insulation (R-38).
12. Provide brace wall details and notes for exterior frame walls and main cross-stud partitions, or use fully braced, per R602.10.3. A minimum panel width of 48" is required to effectively brace the partition. See table R602.10.3, category "C". If bracing does not comply, provide a lateral analysis or alternate design to be reviewed by the plan examiner. Wind forces for single story residences shall use 90 MPH, exposure "B".
13. Detail all brace wall connections from the foundation to the roof plywood.

Plumbing and Mechanical Plan

1. Note and specify all piping materials.
2. Note on plans that shower and tub / shower combinations that have individual control valves shall be of the pressure balance or thermostatic mixing valve type.
3. Note on plan compliance with the water conservation requirements. Water closets, 1.6 gallons per flush, sinks and showerheads, 3 gallons per minute.
4. Provide 2-way cleanout at immediate exterior of new bath.
5. How will hot water be provided to new bathroom?
6. Specify whether gas to new AC unit is new or existing. If new - Provide the length of line to each appliance, BTU demand of each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system per UPC 1217.2.

Electrical Plan

1. Note on plans: Electrical work shall comply wit chapters 33-42 2003 IRC.
2. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11.
3. Submit electrical riser diagram.
4. Provide arc-fault protection for all bedrooms per E3802.11.
5. Show locations of smoke detectors per R313. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms shall be in compliance. When ceiling finish materials are not removed, existing bedrooms shall be equipped with battery operated smoke detectors per R313.1.1. Provide smoke detector in new bedroom.
6. Load calcs are incomplete - Reference table E3604.3(1). Provide a total load in amps for house.
7. Are all circuits to be re-run? If not prove separate panel schedules for each panel and note feeder sizes from new 200-amp panel to 100-amp sub-panel on riser diagram.

MODEL ENERGY CODE:

1. Provide energy calculations per the 2000 IECC and comply with IRC chapter 11 or 'Rescheck' (www.energycodes.gov/rescheck/) that support chosen values

Outdoor Lighting Code

1. Show compliance with City of Tucson Outdoor Lighting Code (www.ci.tucson.az.us/dsd/Codes___Ordinances/Tucson_Lighting_Code.pdf).
2. Provide cut sheets of chosen lights.


If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/06/2005 DELMA ROBEY OUT TO CUSTOMER Completed