Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM01790
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2005 | TERRY STEVENS | ZONING | REVIEW | Approved | |
| 06/28/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 06/28/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 07/05/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 07/05/2005 | LINHART PETERSEN POWERS ASSOC | BUILDING-RESIDENTIAL | REVIEW | Denied | June 30, 2005 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T05CM01790 LP2A Job No. 2050161.012 City of Tucson 201 N. Stone Ave. Tucson, AZ 85701 Re: Plan Review: 8770 E. Bears Path Road Linhart Petersen Powers Associates (LP2A) has completed a review of the following documents on behalf of the City of Tucson: 1. Plans: Two (2) sets of plans (9 sheets, 1 through 10) no date or stamp. 2. Truss Calculations: None provided. 3. Structural Calculations: None provided. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and City of Tucson amended 2003 IBC, 2003 IMC, 2002 NEC and 2003 IPC). Our comments follow on the attached list. Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, LINHART PETERSEN POWERS ASSOCIATES Tom Haney, Senior Plans Examiner ICC Plans Examiner JTH:lw c:\*\Tucson\2050161-012-pc2 enclosures Re: Stories: One Fire Sprinklers: Yes Building Area (sq. ft.): 3,271 (livable) 612 (garage/storage) 803 (porch) A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Building Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are base on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., City Engineering, Public Works, Health, etc.). ARCHITECTURAL COMMENTS: 1. Garage floor surface used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. IRC Section R309.3, Sheet 2 Respond to comment, revise plans as necessary. 2. Provide cross section/details for all stairs. Show riser height and tread depth, handrail details, winding stair (at garage) dimensions, compliance with R311.5 and R312. Sheet 3 Respond to comment, revise plans as necessary. STRUCTURAL COMMENTS: 1. Provide detail showing how to connect interior BWP to roof. 106.3, Sheet 4 Respond to comment, revise plans as necessary. MECHANICAL, ELECTRICAL AND PLUMBING COMMENTS: 1. The mechanical, electrical and plumbing portions have been reviewed and accepted. If you have any questions regarding the above comments, please contact Tom Haney at (602) 864-7600 between 8:00 A.M. to 5:00 P.M., M-F. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/08/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 07/08/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |