Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM01782
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/06/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: June 6th, 2005 ACTIVITY NUMBER: T05CM01782 PROJECT NAME: Estrella Homes PROJECT ADDRESS: 3045 North Estrella Ave. PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. It is acknowledged that a fourteen (14) feet by forty (40) feet for the collection vehicle service area has been provided. However the collection vehicle can not back up into the pedestrian walkway. Be aware refuse vehicles require 36' inside radius and 50' outside radius. Demonstrate manurvability for the collection vehicle. Revise plan accordingly. DS 6-01. Figure 1. 2. The space between the curb and sidewalk within the ROW is a minimum width of two feet. The space is reserved for traffic signs, fire hydrants, etc. Revise the site and grading plan (the site and grading plan must be consistent) to show this space. DS 3-01.2.7.B. 3. On sheet 2, keynote number 3 reads, "Taper 4' sidewalk to curb access ramp." Revise note to read, "Taper 5' sidewalk to curb access ramp." 4. Indicate on the site plan the height of the proposed wall on the property. 5. When PAALs are used as access lanes for refuse collection, a minimum unobstructed radius of eighteen (18) feet is required where they intersect another PAAL. The inside radius is 25 feet for a t-shaped turnaround. The plan shows a radius of 12'. Revise the PAAL to show an inside radius of 25' and outside radius of 18'. Refer to DS 3-01, figure 23 and DS 3-05.2.1.C.3.a. |
| 06/13/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Casalpina pulcherrima and Leucophyllum frutescens will typically grow in excess of 4'. Revise plans as necessary to move plants within SVT. |
| 06/17/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Peter Salonga 199 E. Ft. Lowell Rd. Tucson, AZ 85705 (520) 292-6711 x 101 FROM: Peter McLaughlin Senior Planner FOR: David Rivera Principal Planner PROJECT: T05CM01782 Estrella Homes 3045 N. Estrella Avenue TRANSMITTAL: June 17, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Once completed, provide copies of the lot combination documents including Assessor's lot combo docs and notarized/recorded covenant. 2. The pedestrian circulation system may not pass behind the visitor parking spaces. Revise plan to show a sidewalk passing in front of the spaces rather than a crosswalk behind them. DS 2-08.4.1.F If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/22/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 06/22/2005 | SUE REEVES | REJECT SHELF | Completed |