Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU
Permit Number - T05CM01703
Review Name: RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2005 | HEATHER THRALL | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Heather Thrall Senior Planner FOR: David Rivera Principal Planner PROJECT: T05CM01703 1107 W. Sonora Street New Duplex Site Plan 1st Review Transmittal date: May 17, 2005 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Label elevations to show which wall face is shown, or which direction the viewer is looking (i.e. facing South or South wall). 2. Please label the elevation plans with all dimensions, from grade. Please include porch heights. 3. Please revise the foundation plan to match the floor and site plans, reflecting a wall has been removed from the dining area of the south unit. 4. Please clarify the owner of the property is Sundry Builders on the revised site plan. 5. Label all porches and patios on the revised site plan. 6. The lot to the south is zoned C-2. Please revise the site plan accordingly. 7. Given the zoning to the south of this lot is C-2, the required south setback is equal to the height of the exterior building wall facing the south property line. The height of the exterior building wall facing the south property line -listed on the submitted site plan - is 13 feet. The setback proposed is only 10 feet, 3 feet less than required. To continue with this project as proposed, a Lot Development Option (LDO) must be obtained to maintain the shown reduced south setback. See comment 8 for further information. 8. Should you have any questions on this review, or wish to make an office appointment to obtain official LDO comments, please contact me at Heather.Thrall@tucsonaz.gov or at 791-4541x1156. If you have any questions about this transmittal, please call (520) 791-5608. |
| 05/17/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 05/17/2005 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 05/17/2005 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Approved | |
| 05/19/2005 | GBONILL1 | WWM | REVIEW | Needs Review | |
| 05/19/2005 | GBONILL1 | LANDFILL | REVIEW | Needs Review |