Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T05CM01646
Parcel: 125075740

Address:
2034 E 7TH ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T05CM01646
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/05/2005 GERRY KOZIOL WWM REVIEW Approved
07/05/2005 PATRICIA GILBERT ENGINEERING REVIEW Approved
07/15/2005 NEAL SAUNDERS BUILDING-RESIDENTIAL REVIEW Denied Plan Check Comments - Project T05cm01646

Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

General Requirements

1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned.
2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes.

Floor Plan

1. Specify risers for all new stairs.
2. Note distance from Proposed carport to side property line.

Structural Plan

1. 1/3 - Dimension 6" from post to grade.
2. Justify 4x10 beam over carport or resize.
3. 1/5 - Firewall - Clarify that 5/8" GWB is Type 'X' and applied to the interior face of wall.
4. 4/5 - Clarify 'Stucco System'. If this system includes foam then the placement of ledgers and other structural members is not allowed over it. Foam is not considered a structural member and it effectively leaves a gap between the wall framing and trellis framing. Revise. Also specify the ledger to wall connection and beam to rafter connection.
5. When using 1/2" sheetrock on ceiling with rafters or trusses spaces at 24"o/c, use the sag resistant type per table R702.3.5. Specify.

Plumbing and Mechanical Plan

1. Add clotheswasher to fixture schedule and there are two existing bathrooms at 6 fixture units each. My count for total fixture units (new and existing) is 34. Verify supply line size from meter per table 6.4, 1994 UPC.
2. Bathroom outlet must be dedicated for bathroom only per E3603.4 (note exception).
3. Note that all smoke detectors must be interconnected with a power source from the building wiring, and shall be equipped with battery backup. When ceiling finish materials are removed in existing construction, existing bedrooms shall be in compliance. When ceiling finish materials are not removed, existing bedrooms shall be equipped with battery operated smoke detectors per R313.1.1.

MODEL ENERGY CODE:
1. NOTE: If addition is < 20% of total square footage of dwelling, you are not required to meet MEC requirements.
1. Provide energy calculations per the 2000 IECC and comply with IRC chapter 11 or 'Rescheck' (www.energycodes.gov/rescheck/).
2. Call out on the plan the "U" values of the windows and doors in compliance with the energy calculations provided. Windows must be low 'E'.

Outdoor Lighting Code

1. Show compliance with City of Tucson Outdoor Lighting Code (www.ci.tucson.az.us/dsd/Codes___Ordinances/Tucson_Lighting_Code.pdf).
2. Provide cut sheets of chosen lights.


If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/22/2005 CINDY AGUILAR OUT TO CUSTOMER Completed
07/22/2005 SUE REEVES REJECT SHELF Completed