Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM01437
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/13/2005 | HEATHER THRALL | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Heather Thrall Senior Planner FOR: David Rivera Principal Planner PROJECT: T05CM01437 2220 E. Winsett Street Addition to single family residence Site plan 1st Review Transmittal date: April 13, 2005 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The submitted site plan shows a lot size of 123.75 feet by 50 feet, for a total lot area of 6,188 square feet. Staff reviewed the shown lot size for a possible nonconforming status, as the R-1 zoning of the site requires the minimum lot size to be 7,000 square feet. Staff discovered the Country Club Manor Subdivision was created in 1928, which allows staff to confirm the project lot is legal nonconforming in size. During this research process, staff noted a discrepancy between the lot size shown (listed above) on the submitted site plan, and the lot size shown on the approved subdivision plat. The actual, nonconforming lot size for this property is 113.75 feet by 50 feet, for a total lot area of only 5,687.5 square feet. Please show this information on the revised site plan. 2. Based upon comment 1, both the north and south property line setbacks shown for the residence need to be reviewed and possibly changed to show accurate measurements on the revised site plan. 3. Given the findings in comment 1, please revise the proposed lot coverage calculations on the revised site plan. 4. The submitted site plan highlights the proposed bedroom and family room addition only. Please identify the "patio cover" as part of the proposed addition project as well. 5. Please show all building wall heights as measured from finished grade, rather than finished floor, on the revised site plan. 6. Per the last approved plans, the existing residence contains two (2) bedrooms. The proposed project shows an addition of two (2) bedrooms and a family room. The proposed family room meets the Land Use Code definition of a bedroom (Section 6.2.2, page 429), which will in essence, provide this residence with a total of five (5) bedrooms. Per Section 3.5.7.1.G. and H of the Land Use Code (page 272.1), a five (5) bedroom residence in the R-1 zone must provide three (3) parking spaces. All parking and maneuvering must be contained on site, either in a side or rear perimeter yard. The vehicular use area must be improved, which includes surfacing, striping and provision of barriers, in conformance with Development Standard 3-05. Parking spaces are not permitted in the front street perimeter yard. The front street perimeter yard is defined as the area between the street and the front wall of the residence. Per the Zoning Administrator's determination, any proposed alley access is not allowed to any future proposed parking spaces, and cannot be approved without a Board of Adjustment variance granted to allow access. Given the Land Use Code and Development Standard requirements listed above, the project, as currently proposed, cannot be approved. On the revised site plan, please show a parking and vehicular use area meeting the above listed code provisions. (Please be sure to add the proposed parking and vehicular use areas to the revised lot coverage calculations.) The alternatives are to redesign the project to reduce the number of bedrooms or apply for and obtain a Board of Adjustment variance for parking and access standards, if needed. 7. These are not final comments for an official Board of Adjustment variance referral. Should the applicant wish to seek variances for this project, please contact me for review of any revisions to the proposed plan and for comments to be referred to the Board of Adjustment process. 8. Should you have any questions on this review, please contact Heather Thrall for an office appointment via email at Heather.Thrall@tucsonaz.gov or at 520-791-5608 x1156. If you have any questions about this transmittal, please call (520) 791-5608. |
| 04/18/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 04/26/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/28/2005 | GBONILL1 | OUT TO CUSTOMER | Completed |