Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2005 SEPTIC APPROVAL WWM REVIEW Denied Will a new septic be installed?
04/12/2005 HEATHER THRALL ZONING REVIEW Approved
05/02/2005 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied PLAN REVIEW COMMENTS for Activity # T05CM01369

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

FLOOR PLANS / ELEVATIONS:

1. Show that each water closet is located in a clear space not less than 30" wide and has a clear space in front not less than 21" per figure R307.2.
2. Shower glass enclosures/doors shall be tempered R308.4.
3. Show compliance with R310 providing egress from bedrooms with a maximum sill height of 44".
4. All wood framing members that rest on concrete (stairway stringers) shall be protected against decay R319.1.

SECTIONS - DETAILS - MISC. NOTES:

1. Note and specify the size, spacing and length of anchor bolts for sill plates, top plates and ledgers.
2. Notes shall be referenced to the floor plan (#6 on sheet E101).

PLUMBING PLANS:

1. Shower floors and walls shall be finished with nonabsorbent surface R307.2.

ELECTRICAL PLANS:

1. At least one GFCI receptacle outlet shall be installed in the attached garage R3801.9 & E3802.2.
2. An arc-fault circuit interrupter shall protect bedroom outlets R3802.11.
3. At least one wall switch controlled light or outlet must be provided in bathrooms, hallways, stairways, attached garages, outdoor entrances or exits and all habitable rooms per E3803.3.
4. Smoke alarms are required outside each separate sleeping area R313.1.2.


If you have any questions, please contact your assigned plans examiner Ken Van Karsen at 791-5550, extension 1112.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/05/2005 ANGIE SHOFFSTALL REJECT SHELF Stop
03/28/2005 ANY OUT TO CUSTOMER Stopped