Permit Number: T05CM01286
Parcel: 133369570

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T05CM01286
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/23/2005 JIM EGAN FIRE REVIEW Approved
03/23/2005 RAUL PALMA BUILDING-COMMERCIAL REVIEW Approved
03/23/2005 PATRICIA GEHLEN ZONING REVIEW Approved
03/23/2005 PATRICIA GILBERT ENGINEERING REVIEW Approved
03/24/2005 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Show that the existing 1" water pipe will not be overloaded with the addition of the new fixtures. Include the head losses (e.g. meter, RPBP losses, lift) when determining the available static pressure for use in Table 6-4.
2. Provide the size of the waste line from the lav to show that the waste line from P1 can be accommodated.
3. Provide a description of P2 and show the size of the proposed waste line.
4. Show how the water heater is mounted.
5. The water heater detail calls for a drain line to be routed to a service sink or a floor sink. Show the route and termination of the drain line on the plans.
6. The minimum trap size for a clotheswasher is 2".
03/24/2005 BOB SUBA ELECTRICAL-COMMERCIAL REVIEW Approved
03/24/2005 ROBERT SHERRY WATER REVIEW Approved
03/24/2005 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Verify the exhaust volume for the restroom complies with the requirements of Section 403.3, IMC 2000. Provide a sequence of operation for the fan to show that there will be no recirculation of the supply air from the restroom.
04/05/2005 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/05/2005 KMEDINA1 OUT TO CUSTOMER Completed