Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T05CM01242
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/09/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 11/10/2005 | PETER MCLAUGHLIN | ZONING HC SITE | REVIEW | Denied | See Zoning Review Comments. |
| 11/10/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Mark Allen Begurski 4101 E. Speedway Blvd. Tucson, AZ 85712 (520) 909-9572 FROM: Peter McLaughlin Senior Planner Development Services Department FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T05CM01242 Change of Use- Car Sales 4101 E. Speedway Blvd. Site Plan Review (2nd review) TRANSMITTAL: November 10, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Revise the slope of the handicapped parking aisle to be no more than 1:48 as required ANSI/IBC 2. The two-way PAAL located east of the building must be a total minimum of 25 feet in width (24-foot PAAL plus an additional 1-foot setback for the open structure overhang). Revise plan to dimension width of PAAL at minimum 25 feet between the parking spaces and the edge of roof overhang. DS 2-02.2.1.A.13 DS 3-05.2.2.B.2 3. Revise scale on sheet 4 of 4 to be correct. DS 2-02.2.1.A.1 4. Please dimension clearly all MS&R street monument lines from Speedway centerline, including existing and future curbs. DS 2-02.2.1.A.21 5. Place a note on the plan stating that the project is designed to meet the criteria of Sec. 2.8.3, MS&R setback zone. LUC 2.8.3 6. On sheet 2 of 4, revise the label for the "possible future property line" by removing the word "possible. DS 2-08.4.1 7. Dimension the existing building at its closest point from back of future curb location. LUC 3.2.6.5 8. All lettering and dimensions must be a minimum of 12 point (0.12") in size for microfilming purposes. On all sheets revise all text that does not meet this minimum archiving standard. 9. Label and delineate the area to be used for vehicle display and indicate that there is sufficient PAAL width in all areas adjacent to the vehicle display area. 10. Other than adjacent zoning, remove the adjacent property sign details and other adjacent property elements from the drawing as these will not be approved as part of this site review. DS 2-02.2.1.A.28 11. If the dumpster shown on sheet 4 of 4 is proposed, show it on all sheets to be consistent. 12. Indicate the height and dimensions of the proposed Y2K sign and dimension its distance from the back of future curb location. DS 2-02.2.1.A.13 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 11/15/2005 | PETER MCLAUGHLIN | NPPO | REVIEW | Approved | |
| 11/15/2005 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1) Submit a separate landscape plan per DS 2-07.0 showing all required landscaping and screening. Per table 3.7.2-I, a street landscape border and a 30-inch high screen is required. The screen must be continuous and must be placed on the development side of the street landscape border. 2) Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage on the landscape plan per DS 2-07.2.2.2.g. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4 3) Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. 4) Landscape borders along parking lot and vehicle use areas where plants are susceptible to injury by vehicular traffic must be protected by appropriate means, such as curbs, bollards, or low walls per LUC 3.7.2.3.B. Provide protection for landscaped areas. 5) The Landscape plan shall include irrigation specification design and layout per DS 2-07.5.4.A & DS 2-07.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation. 6) Provide symbols on the plant legend. Revise all plant symbols used on the plan to be representative of the ultimate size of the plants at maturity indicated by the spread of canopy, circumference of shrubs, or spread of ground cover. The number, spacing and placement of the oleanders shown on the landscape plan is not appropriate for its size and growth characteristics. There are too many oleanders proposed. State the specific type of oleander proposed. There are many varieties of nerium oleanders, some of which can grow in excess of 15-20 feet in height. Shrubs within sight visibility triangles and within 4 feet of walkways shall be no higher than 30". Revise. DS 2-07.2.2.A.1.c DS 2-06.3.5.B 7) Further comments may be necessary once revisions are made. |
| 11/18/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: November 18, 2005 ACTIVITY NUMBER: T05CM01242 PROJECT NAME: Change of Use; Car Lot PROJECT ADDRESS: 4101 East Speedway Blvd PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. Submit the last approved site plan. 2. Change the verbiage in the title block from "Change of Use Plan" to "Site Plan." The above comment is from the first review. It is still not clear which plan is the site plan. Sheet 2 is labeled "Record of Survey," and shows a significant amount of required site plan information. Sheet 3 is labeled "Change of Use Plan," which appears to be the site plan. Sheet 4 is labeled "Record of Survey," and shows landscape information and solid waste requirements. Solid waste requirements must be on the site plan. The plan set that has been provided is confusing. Each plan sheet should show specific requirements, i.e. Development Standards 2-02 Site plan content must be shown on one sheet, the landscape information on another sheet. Revise the plan set for clarity. 3. Label and show the existing sidewalk along Speedway Blvd. Dimension the sidewalk and label the length on the plan. Is the sidewalk existing or proposed? Clarify and label accordingly. Revise. 4. All lettering and dimensions will be the equivalent of twelve point or greater in size. The purpose of this requirement is to assure that the lettering is legible when reproduced or microfilmed for record keeping purposes. The some of the current font measures to 10 point, it must be at least 12 point or greater in size. Revise all lettering to be at least 12 point. 5. A minimum setback distance of five (5) feet for a pedestrian refuge area must be maintained between any enclosed structure and a PAAL. Provide a sidewalk and pedestrian refuge between existing PAAL and the northern end of the structure. See Redlines. Revise plan as necessary. DS 3-05.2.2.B.1., Figure 1 and DS 2-08.4.1.B. 6. Dimension from street centerline to the existing curb, future curb and sidewalks. 7. New development will provide on-site refuse storage, collection, and pickup area with service access from within the tract. Each service area is required to have a clear approach of fourteen feet by forty feet for the collection vehicle. The maximum back-up distance for the collection vehicle shall be forty feet. For further information on site compliance for solid waste refer to Development Standard 6-01. The comment above is from the first review. Provide written approval for the response to the above comment. The response is noted on sheet 3 in the general notes. Provide written approval from the solid waste department. 8. For a PAAL/Driveway off of an arterial street (Speedway Blvd.) 25' curb return radii is required. Indicate 25' curb return radii for the ingress/egress off of Speedway Blvd. DS 3-01. Figure 6. The comment above is from the previous review. The response to this comment is The Traffic Engineering Department approved this submittal. Provide written approval from the Traffic Engineering Department. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/29/2005 | GBONILL1 | OUT TO CUSTOMER | Completed |
| 11/29/2005 | SUE REEVES | REJECT SHELF | Completed |