Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00990
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/29/2006 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The water heater T&P relief appeal requires the installation of a pressure relief valve on the outside of the building in addition to the installation of a drip pan under the water heater. 2. Multi-use commercial property requires the use of a reduced pressure principle assembly after the water meter, not a double check valve. A Watts model 007M1QT is a double check valve. 3. Provide a shut off valve for the new water service at the building entrance. Reference Section 605.3, UPC 1994. |
| 06/29/2006 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/30/2006 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide the total amount of circulation air and the total amount of outside air (CFM) to be supplied by the air conditioner. Provide a balance report to the mechanical inspector to demonstrate that the system is functioning as designed. Reference Section 603.1, IMC 2000. 2. The installation of an exhaust fan in the laundry room with no direct source of outside air in the adjoining room is insufficient to provide ventilation conforming to Section 403.3, IMC 2000. Air to be transferred must have been directly introduced into the space from which it is to be transferred and in sufficient amounts to provide adequate ventilation for both spaces (i.e. ventilation air cannot be reused). Reference Section 403.2.2, IMC 2000. 3. The kitchen has an inadequate opening (less than 25 square feet) to the lounge, from which it is to receive its natural ventilation. The opening to the laundry cannot be considered because it has no openings to the outside. Reference Section 1202.4, IBC 2000. 4. Show that the south massage room has a return register per Section 7-137 (3), Ordinance 9991 for the City of Tucson.) |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/18/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 07/18/2006 | SUE REEVES | REJECT SHELF | Completed |