Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00918
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/26/2005 | LINHART PETERSEN POWERS ASSOC | BUILDING-RESIDENTIAL | REVIEW | Approv-Cond | May 25, 2005 CITY OF TUCSON - SECOND CHECK Tucson Appl. No. T05CM00918 LP2A Job No. 2050161.003 City of Tucson 201 N. Stone Ave. Tucson, AZ 85701 Re: Plan Review: Frank and Katie Flasch Residence Address: 2909 N. Santa Rosa Pl. Linhart Petersen Powers Associates (LP2A) has completed a review of the following documents on behalf of the City of Tucson: 1. Plans: Three (3) sets of plans (9 sheets, 1A through 8 of 8) no date or stamp. Two (2) sets of Joist Plans, not dated or stamped. Two (2) sets of foundation plans (3 sheets S1 through SD1) not dated or stamped. 2. Truss Calculations: None provided. 3. Structural Calculations: Two (2) sets of structural calculations dated May 23, 2005, by Alvand Consulting Engineers, Inc. These documents were reviewed only for their conformance to the provisions of the 2003 International Building Codes (i.e., State of Arizona and City of Tucson amended 2003 IBC, 2003 IMC, 2002 NEC and 2003 IPC). Our comments follow on the attached list. Please submit an itemized response letter and required number of complete and revised documents with all revisions clouded. Sincerely, LINHART PETERSEN POWERS ASSOCIATES Tom Haney, Senior Plans Examiner ICC Plans Examiner JTH:lw c:\*\Tucson\2050161-003-pc2 enclosures Re: Stories: One Fire Sprinklers: Building Area (sq. ft.): 2,194 (livable) 457 (porches) 645 (garage) A. The following plan review comments are based on the City of Tucson Building Regulations and referred to the 2003 International Building Code. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re-check and hopefully, approval of this project. Thank you for your assistance. C. These plan review comments are base on building code items only. If site-related comments are applicable to this project, they will be generated by others (e.g., City Engineering, Public Works, Health, etc.). ARCHITECTURAL COMMENTS: 1. Provide attic vent calculations and show type and location of vents. IRC R806, Sheet 7 Provide unvented attic detail on plan. STRUCTURAL COMMENTS: 1. Provide wall bracing diagram in compliance with R602.10 or provide engineered lateral analysis. Plans examiner has attempted to redline an acceptable wall bracing diagram. Some areas require engineering. R602.10.1, Sheet 1 Provide details for braced panel method 5 drywall. R602.10.3 2. Specify stucco material to be used and provide ICC ES number. Sheet 2, IRC 106.1.1 Please provide requested information. PLUMBING, ELECTRICAL AND MECHANICAL COMMENTS: 1. The plumbing, electrical and mechanical portions have been reviewed and accepted. If you have any questions regarding the above comments, please contact Tom Haney at (602) 864-7600 between 8:00 A.M. to 5:00 P.M., M-F. |
| 05/27/2005 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 05/27/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 05/27/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved |