Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T05CM00833
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2005 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise the water pressure and water pipe sizing calculations per Sections 610.4 and 610.7, UPC 1994. 2. Revise the design water pressure used in the calculations in accordance with Section 610.7 (5), UPC 1994. |
| 02/24/2005 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/24/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide calculations to show that the facility has adequate ventilation. Reference Section 403.3, IMC 2000. |
| 02/25/2005 | DMANN1 | FIRE | REVIEW | Passed | |
| 02/25/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 02/25/2005 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | 1) Toilet room #2 - turning radius clear of door swing. 2) Toilet room #2 - provide water closet clearance. 3) Provide wall section for interior partition / connections at top and bottom. 4) Occupant load over 15 therefore provide 1 female and 1 male restroom facility. See code section 2902.2. |
| 02/25/2005 | CRAIG GROSS | ZONING | REVIEW | Approved | |
| 02/25/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T05CM00833 DENIED 2/25/05 Please clarify subfeed to Ckts 13-20. Discuss with Electrical Plans Examiner. |
| 02/25/2005 | MATT FLICK | ENGINEERING | REVIEW | Approved | No floodplain per FIRM. Existing civil facilities. TI only. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/01/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 03/01/2005 | SUE REEVES | REJECT SHELF | Completed |