Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE
Permit Number - T05CM00825
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/14/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or Application for Exception per DS 2-15.0 |
| 03/25/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: March 25, 2005 ACTIVITY NUMBER: T05CM00825 PROJECT NAME: Duplex PROJECT ADDRESS: 439 East Linden PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. A minimum of 12' is required for one way access. Provide 12' for access to unit "B" garage. DS 3-05.2.1.C. |
| 03/28/2005 | HEATHER THRALL | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Heather Thrall Senior Planner FOR: David Rivera Principal Planner PROJECT: T04CM00825 439 E. Linden St. New duplex Site Plan Transmittal date: March 28, 2005 1st Review COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Please provide the owner of the property on the resubmittal. 2. The height of the south building wall, facing Linden Street, is required on the revised site plan. The measurement should be taken from finished grade to the top of the wall. 3. Please indicate the property is addressed on East Linden Street in the revised drawings. 4. Staff noted the address and lot size of the submitted plan indicates a lot split occurred. Please provide a copy of the city approved lot split creating two lots from the original site, 439 E. Linden Street. 6. Per the submitted floor plan, the proposed duplex will have a total of six (6) bedrooms. Per the Land Use Code, five (5) parking spaces are required for this number of bedrooms. The submitted site plan indicates four (4) of the required parking spaces shall be located in separate two car garages on site. Given the fourteen (14) foot setback projected from one garage to the west property line, vehicle maneuverability needs to be demonstrated on the revised site plan, as the garage will be providing parking for two required parking spaces. 7. Should you have any question regarding this review, please contact me at Heather.Thrall@tucsonaz.gov or at 520-791-5608x1156 to make an office appointment. If you have any questions about this transmittal, please call (520) 791-5608. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/29/2005 | GBONILL1 | OUT TO CUSTOMER | Completed |
| 03/29/2005 | SUE REEVES | REJECT SHELF | Completed |