Permit Number: T05CM00658
Parcel: 131010120

Review Status: Completed

Review Details: OTHER

Permit Number - T05CM00658
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/22/2005 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
02/28/2005 BOB SUBA ELECTRICAL-COMMERCIAL REVIEW Approved
03/17/2005 CHRISTY FOREMAN BUILDING-COMMERCIAL REVIEW Denied CITY OF TUCSON DEVELOPMENT SERVICES
STRUCTURAL REVIEW COMMENTS

DATE: 3/22/05
ACTIVITY NUMBER: T05CM00658
PROJECT NAME: Replace Inlet piping & upgrade elect.
PROJECT ADDRESS: 1255 S. Beverly Ave.
ARCHITECT / ENGINEER: Dorothy Dolan
PROJECT REVIEWER: Christy Foreman



TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS.

1) Clarify chemicals if any stored on site.
2) Detail riser heights for stairs see section 1009.3 & 1009.3.2
3) Hand rails @ stairways per section 1009.11 - height, extensions, & graspability.
4) Grating support detail 1, and section 2 - sheet 18 of 35. Details require ¼" x 7" x cont. strap. Structural calculations specifies ¼" x 8" x cont. strap.
5) Special Inspection Forms will need to be provided before permit can be issued.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/23/2005 TAMI ACHONG OUT TO CUSTOMER Completed
03/23/2005 SUE REEVES REJECT SHELF Completed