Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00421
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/27/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
05/06/2005 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Approved | |
05/10/2005 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. The proposed sump pump installation does not comply with the manufacturer's requirements for venting (i.e. " Do not cap off vent or use one-way quick-vents." Liberty Pumps, installation instructions for Model 403). 2. The sink is in public use and as such, requires a duplex sump pump. Reference Sections 710.9, UPC 1994. |
05/16/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/19/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
05/19/2005 | SUE REEVES | REJECT SHELF | Completed |