Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/WWM
Permit Number - T05CM00409
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/17/2005 | GERRY KOZIOL | WWM | REVIEW | Denied | needs 8th floor credit evaluation- Yvonne 740-6500 |
| 03/10/2005 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T05cm00409 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. Foundation Plan 1. 7/2 - Provide #4 rebar at top of stemwall bond beam. 2. 11/2 - Dimension 12" below grade. Floor Plan 1. Provide access to each separate attic that exceeds 30SF per R408.3 and R807. Designate locations on the drawings. Openings shall not be less than 22"X30" for attics. Attic access shall provide a minimum of 30" of headroom, and shall be located in a hallway or readily accessible space. 2. Identify ceiling heights in all areas on floor plan. If sloped ceiling, note average height. 3. Appliances installed in garages shall be mounted on platforms at least 18" above the floor, per M1307.3. 4. General note 15, page 3 - 1024 sq. in. rather than 900. 5. Provide energy calculations per the 1998 IECC and comply with IRC chapter 11 that support chosen values. Structural Plan 1. Built-up roof or shingles? Conflict between elevations and cross- sections. Tile roof? (Details). Clarify. Also, insulation cannot be on underside of roof deck in an asphalt-shingled roof. Revise plan and provide attic ventilation per R806.2 for a shingled roof. 2. 13/10 - Callout top plate. 3. 10/10 - Provide cross bracing at gable end per R802.10.3. 4. Size lintel over hallway door to new garage. Is it sufficient to carry new roof load? 5. 18/10 is misplaced at back porch beam. 6. 18/10 is misplaced at front porch beam. It should be 17/10. 7. Specify and detail all over-framing. If solid sheathing is used on the lower trusses, provide minimum openings of 22" by 30" for access and ventilation into over-framed areas (>30 S.F.). If solid sheathing is not used on lower trusses, provide details for bracing of top chord of lower trusses. 8. 6x8 beam at front porch is inadequate for a 2 point bearing truss. Submit truss calcs or specify truss bearing conditions. Plumbing plans 1. Size gas line from meter to furnace. Minimum is 1-1/4" per table 12-3, 1994 UPC. 2. Provide and locate pressure and temperature relief valve at water heater. T&P line must terminate at the exterior between 6 and 24 inches above grade and must terminate facing down. 3. Size meter and supply line(from meter to house). With 51 fixtures, 120' of developed length and specified pressure, a 1" meter with 1-1/2" supply line is required per table 6-4, 1994 UPC. Mechanical and Electrical Plans 1. Locate and size return air per IRC sections M1602.2. (gas furnace - 2 sq. in. / 1000 BTU; heat pump / air conditioner - 6 sq. in. / 1000 BTU) (1ton cooling = 12,000 BTU) for both systems. 2. Gas appliances shall comply with ARIZONA STATE PLUMBING CODE combustion air requirements. Detail how you will comply. Water heater and new Furnace. 3. Note the location, type and amperage of the panel. Note the grounding and bonding method. Metallic gas lines must be bonded and shall not be used as grounding method. 4. Submit electrical riser diagram. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/11/2005 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 03/11/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |