Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00401
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/04/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: October 4, 2005 ACTIVITY NUMBER: T05OT00736/T05CM00401 PROJECT NAME: Tenant Improvement PROJECT ADDRESS: 510 North Stone Ave. PROJECT REVIEWER: Patricia Gilbert FLOODPLAIN USE PERMIT IS DENIED SITE PLAN IS DENIED RESUBMITTAL REQUIRED: SITE PLAN, CONTRACTOR'S ESTIMATE, 2005 PIMA COUNTY ASSESSOR'S RECORD OR APPRAISAL FROM A LICENSED APPRAISER, FLOODPLAIN USE PERMIT APPLICATION 1. This structure was built prior to 1982 when the Floodplain Ordinance came into effect. The structure is considered a non-conforming structure within a FEMA Flood Hazard Area, Zone AE. If the cost of improvements or repairs is 50% or less of the current market value of the structure it is considered a non-substantial improvement. The value of the structure and a contractor's estimate is required to determine if the improvements are less than 50%. Submit a contractor's estimate of the proposed work, labor and materials and the 2005 Pima County Assessor's Record (value of structure). |
10/31/2005 | RAUL PALMA | BUILDING-COMMERCIAL | REVIEW | Denied | City of Tucson, Development Services BUILDING AND STRUCTURAL COMMENTS 04/19/05 1) Provide the engineers seal on the structural sheets. 2) Provide engineering calc`s for the lintel at the overhead door. 3) Provide engineering for the roof members for any equipement on the roof. 4) Provide a phy. Handicapped bathroom. Show all details. 5) Building shall be made accessible to the Phy. Handicapped. 6) Is upper level existing? If so indicate on plans. 7) Specify the uses and occupancy(s) group of the building. It appears like there is more than one occupancy or use. Clarify! 10/27/05 1) Provide connection details for grab bars to wall. 2) section 303.3 of the 2003 ANSI standards the physically handicapped specifies that any changes in level greater then ¼" in height but less then ½" shall be beveled. 3) Egress from a room or space shall not pass through adjoining or intervening rooms. Section 1013. 4) Identify on plans as to which are the partitions and which are the trusses. 5) Ground level floor plan shows a beam, truss. or wall being removed, specify what it is. 6) Are the spaces above shown as offices existing office spaces? Varify! 7) Specify width of exit door leading to physically handicapped bathroom, and also exiting out of the building. 8) Are all overhead doors exiting? |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/08/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
11/08/2005 | SUE REEVES | REJECT SHELF | Completed |