Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00400
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/12/2005 | HEATHER THRALL | ZONING | REVIEW | Approved | |
| 04/26/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS PROJECT #T05CM00400 04/26/05 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, model energy and electrical. All code references are to the 2003 International Residential Code, 2000 International Energy Conservation Code, and Arizona State Plumbing Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia & (1) blue line shall be returned along with all redline prints. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. SITE PLAN: 1. Indicate the location of gas, water, electric and sewer or septic line on the property, and where they enter the building. ------------How will new water and gas lines be installed under existing carport? Gas lines are not allowed underground under a roofed structure. Is a new gas meter being installed next to new guest house? FOUNDATION PLANS: 1. Dimension the height above natural grade to sill plate at detail 1/5, min. 6". 2. Locate and specify all anchor-bolt minimum ½" diameter with 7" embedment into concrete or masonry. FLOOR PLANS: 1. Individual dwelling units in duplexes must be separated by a 1 hour fire wall from floor to bottom of roof sheathing per IRC section R317.1.---------PROVIDE CROSS SECTION DETAIL of how the 1 hour wall will be constructed STRUCTURAL PLANS: 1. Completely detail all connections and cross-reverence to the foundation and framing plans: - I-joists to nonbearing wall 2. NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. REVISE ALL PLANS TO REFERENCE THESE CODES. If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/27/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 04/27/2005 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |