Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE
Permit Number - T05CM00235
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/25/2005 | PATRICIA GEHLEN | ZONING | REVIEW | Approved | |
| 03/25/2005 | DOUG WILLIAMS | ENGINEERING | REVIEW | Approved | BY DWILLIAMS FOR LM |
| 03/31/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | Plan Check Comments - Project T05cm00235 Plan Review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating action taken. General Requirements 1. All corrections and revisions shall be made on the original tracings and two new sets of prints or (1) sepia and (1) blue line shall be returned. 2. Pen or pencil corrections on final prints will not be acceptable. To avoid delays ensure that corrections have been made, are complete and have been coordinated on all-applicable details and notes. Structural Plan 1. Specify landing at bottom of stairs per R311. Also provide stringer connection to slab (i.e. footing with plate and anchor bolts). (rear deck) 2. LCB column bases are not recommended for non-top supported installations (see manufacturers recommendations). Provide lateral analysis to justify structure. (rear deck) 3. 1/A2, Section A and Section B - HU310 is for a 3x10 joist. Joists on plan are called out as 2x10. Clarify. (front porch) 4. 1/A2 and section B - Specify spacing of ledger bolts. (back porch) 5. Section B - Is there a post from the post footing or just an EPB44T? Floor framing calls out a 6" post (EPB66T?) while section B suggests the post base attached directly to the girder. Clarify. (front porch) 6. Specify post bases for 4x6 post. (front porch) If you have any questions, please contact your assigned plans examiner Neil Saunders at 791-5550, extension 1113. NOTE: As of 09/06/04 the City of Tucson has adopted the 2003 IRC with the exception of the plumbing portion which has been replaced with the Arizona state plumbing code. All model plans shall reference these codes. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/07/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 04/07/2005 | SUE REEVES | REJECT SHELF | Completed |