Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00017
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/27/2005 | GERRY KOZIOL | WWM | REVIEW | Denied | needs to show public sewer & public sewer easement on site plan |
05/02/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | 1. Detail 4x8 beam connection to existing adobe wall. 2. Trusses are not provided for framing around chimney. Provide truss layout and appropriate girder trusses to match conditions on plans. 3. L1 in calcs call for (2) 6x 3-1/2x 5/16 steel while plans note use of existing lintels. Clarify. 4. Section R614 - Earthen Wall Structures; Bond beam does not meet prescriptive design. Comply with R614 or provide engineering for continous bond beam. 5.10/A9 - Provide gable end cross bracing. Any questions contact Neil Saunders @ 791-5550 x1113. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/05/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
05/05/2005 | SUE REEVES | REJECT SHELF | Completed |