Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T05CM00003
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2005 | MATT FLICK | ENGINEERING | REVIEW | Passed | No floodplain or significant engineering issues. |
| 03/11/2005 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 03/17/2005 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide calculations demonstrating adequate ventilation. Reference Section 401, IMC 2000. 2. Provide information to show that the termination of the restroom exhaust complies with the requirements of Section 401.5.2, IMC 2000. 3. Specify the minimum resistance (R-value) of the duct insulation to be used duct that is not exposed within the conditioned space. Reference Section 803.2.8, IECC 2000. |
| 03/17/2005 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Include the water demand for the mop sink in the water demand calculation. Reference Section 610.1, UPC 1994. 2. Calculate the water demand of items not specifically listed in Tables 6-3 or A-2 at their maximum demand but at not less than the fixture units for water supply outlets shown at the bottom of Table 6-3. Reference Section 610.3, UPC 1994. 3. One of the specified fixtures (espresso machine) may require a minimum pressure greater than the 20-PSI used in the water pipe sizing calculations. Confirm and revise calculations as necessary. Reference Section 608.1, UPC 1994. 4. The backflow preventer specified for the espresso machine (Conbraco model 40-400) is not approved for use with directly connected appliances that produce backpressure. Reference Table 6-1, UPC 1994. 5. Based on the provided calculations, the ¾" water supply to the building is unable to handle more than 11 fixture units. Reference Section A4.1, UPC 1994. 6. All storage-type water heaters require a listed expansion tank. Please show expansion tanks on plans. Reference Section 608.3, UPC 1994 with AZ State amendments. 7. If the specified water heater is not supplied with integral heat traps, provide heat traps (not bent flexible connectors) on the supply and discharge piping. Reference Section 804.4, IECC 2000. 8. Provide ½" insulation on the first eight feet of supply and discharge piping for the water heater. Reference Section 804.5, IECC 2000. 9. The specified lavatory faucets are designed for a flow rate of 2.2 GPM. According to ARS Title 45, Chapter 1, Article 12, the maximum flow rate for lavatory faucets shall be no more than an average of one-half gallon of water per minute at a pressure of eighty PSI or they shall be equipped with a mechanism that causes the faucet to close automatically after delivering no more than one-fourth gallon of water. Reference Section 402.1, UPC 1994, as amended by the State of Arizona. 10. Provide upper terminal cleanouts on horizontal drainage pipe over 5 feet in length (e.g. the branch with P-1A and P-4A). Reference Section 707.4, UPC 1994. |
| 03/17/2005 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 03/23/2005 | CHRISTY FOREMAN | BUILDING-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES STRUCTURAL REVIEW COMMENTS DATE: 3/1/05 ACTIVITY NUMBER: T05CM00003 PROJECT NAME: Tattoo / Office PROJECT ADDRESS: 561 N. 4th Ave. ARCHITECT / ENGINEER: Paul Kilonzo Nzomo PROJECT REVIEWER: Christy Foreman TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL. PLEASE CALL AT 791-5550 X1108 OR EMAIL AT CFOREMA1@CI.TUCSON.AZ.US IF YOU CARE TO DISCUSS. 1) Show all of building to clarify most restricted use to clarify / justify Nonseparated use or clarify separation between tenants for separated use. 2) Clarify what is 'M' occupancy. 3) Provide approved shop drawing for stairs. 4) Accessibility into restroom see ANSI A117.1 - 2003, Fig. 404.2.3.1. 5) Dimension accessibility for restroom clearance from reception desk to wall. 6) Dimension accessibility clearance into breakroom. 7) Clarify what is above breakroom piercing station. 8) Provide wall section for new partition walls. |
| 03/29/2005 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/31/2005 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Building plans will be reviewed and approved once the site plan is approved. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/31/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |