Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE
Permit Number - T05CM00002
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2005 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 01/05/2005 | Blanca Espino | ENGINEERING | REVIEW | Denied | Site Plan 1. A grading review/permit is required. You can pick up a grading application with the permit clerks and submit grading plan for review. Include 2 copies of the stamped approved Site/Plot plan. 2. Indicate FFE for proposed structure. Indicate WSE. 3. Indicate existing block masonry wall. Indicate symbol in legend. 4. Indicate a note indicating this site is in a '"FEMA floodplain Zone AE, Panel 2227K". |
| 01/31/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael St.Paul FOR: Patricia Gehlen Planning Technician Principal Planner PROJECT: T05CM00002 1316 East 8th Street Stem wall only TRANSMITTAL: January 28, 2005 DUE DATE: January 28, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. This plot plan is in the R-2 Zone. All the adjacent properties are R-2. The site is at present one lot. Please remove the property lines depicting a lot split. LUC Sec 2.3.5.2.A 2. Identify the plan as proposed stem wall and remove proposed structure. 3. Remove any and all references to "unincorporated Pima County." The City of Tucson is an incorporated area. |
| 02/01/2005 | David Witt | BUILDING-RESIDENTIAL | REVIEW | Approved | PLAN CHECK COMMENTS - PROJECT #T05CM00002 2/1/05 1316 E. 8th PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2003 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 4. LIST THE SQUARE FOOTAGES FOR ALL THE FOLLOWING AREAS SEPARATELY ON THE DRAWINGS: - LIVABLE AREA - GARAGE - PORCH/PATIO COVERS - DECKS 5. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF THE STATE BOARD OF TECHNICAL REGISTRATION. FOUNDATION PLANS: PROVIDE A FOUNDATION PLAN. U-FER? IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/04/2005 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 02/04/2005 | SUE REEVES | REJECT SHELF | Completed |