Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Permit Number - T05BU02815
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/NPPO
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2006 | DAVID RIVERA | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: David Rivera Principal Planner PROJECT: T05CM02815 613 N Venice Avenue Single Family Residence - Proposed carport addition TRANSMITTAL DATE: January 21, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Please submit a copy of the last DSD approved and stamped site plan and building plans. 2. It appears that several building or additions may have been constructed without permits. The last plan on file with DSD does not indicate the addition to the South or the East sides of the building. Also it appears that a new storage shed has been constructed in the rear of the property. Label the building height of both the shed structures. Also in review of the aerials it does not appear that the setbacks as labeled on the plan are correct. Please correct as required. 3. In order to verify lot coverage the building footprint must be please dimensioned completely. 4. The location of the proposed carport cannot approved be as proposed without approval through a variance by the Board of Adjustments. The location of the carport as proposed does not meet the required street perimeter building setback of the greatest of 20 feet or one and one-half the height of the structure. LUC section 3.2.6.5.A Also the street building setback for the carport must meet the minimum building setback of 18 feet from the property line as required per LUC section 3.2.6.5.2.a 5. The Board of Adjustment case number, date of approval, and conditions of approval must be listed on the plan. Include a copy of the Board of Adjustment approval letter with the next submittal. Please ensure that all changes are made to the plan and that all necessary documents as requested are submitted with the next submittal package for review prior to submittal to the Board of Adjustments for the variance. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. DGR C:\planning\cdrc\DSD\T05BU02815.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan, B. of A. approval letter, and additional requested documents |
| 12/08/2005 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 12/09/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | NON-SUBSTANTIAL IMPROVEMENT Date: December 9, 2005 Address: 613 North Venice Ave Permit Numbers: T05OT02917 / T05BU02815 Floodplain type: X Shaded / COT Description of Work: Carport Type permit: Residential Year of construction of existing structure: 1949 Value of work: $ 7,250 Prior permit activity value $ 0 Value of structure: $ 56,209 Increase in Flood Damage Potential: % 13 |
| 12/28/2005 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/02/2006 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 02/02/2006 | SUE REEVES | REJECT SHELF | Completed |