Permit Number: T05BU02722
Parcel: 11306203A

Review Status: Completed

Review Details: RESUBMITTAL - GRADING ALL

Permit Number - T05BU02722
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/19/2006 ANDREW CONNOR NPPO REVIEW Denied Site plan approval is necessary to continue review.
06/23/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: June 26, 2006
ACTIVITY NUMBER: T05BU02722
PROJECT NAME: Tucson Chinese Baptist Church
PROJECT ADDRESS: 2411 East Fort Lowell Road
PROJECT REVIEWER: Patricia Gilbert

The following items must be revised or added to the grading plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: 4 COPIES OF THE GRADING PLAN

SUBMITTAL REQUIRED: 4 COPIES OF A STORMWATER POLLUTION PREVENTION PLAN.

1. A copy of the stamped approved Site Plan must be included with the Grading Plan submittal.

2. The Site Plan is currently in review. Any changes made to the Site Plan must be reflected on the Grading Plan. The Site Plan and Grading Plan must match.

3. This site is 1.61 acres. Any construction site that has over an acre of disturbance is required to have Stormwater Pollution Prevention Plan (SWPPP). It is clear the proposed development is over one acre. It has been requested several times to submit a Stormwater Pollution Prevention Plan with the Grading Plan resubmittal. The grading plan will not be approved without a City of Tucson approved SWPPP. The grading plan the SWPPP must be submitted together and the SWPPP must be approved prior to the grading plan submittal. Submit a SWPPP with the next submittal of the grading plan.

4. It is acknowledged that a concrete header (Standard detail 213) has been provided to promote water harvesting into one of the landscape islands. This seems to be an extensive solution to promote water harvesting and costly to the owner. It is also not clear how the parking lot surface drainage is entering the other landscapes areas. It is recommended to simply provide small curb openings in an area with the lowest surrounding grades adjacent to the landscaped island/borders. The small landscape islands only need one opening and it is recommended to provide two openings for the street landscape border. Discuss in detail in the response letter why concrete header (Standard detail 213) has been provided to promote water harvesting or revise the grading plan to show the above recommended solution to promote water harvesting.

5. Be aware the Traffic Engineering Department recommends to provide a "Do Not Enter Sign," at the exit driveway. Revise appropriately.
08/08/2006 TERRY STEVENS ZONING REVIEW Denied 08/08/06

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/01/2006 CINDY AGUILAR OUT TO CUSTOMER Completed
09/01/2006 SUE REEVES REJECT SHELF Completed