Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05BU02233
Parcel: 107060560

Review Status: Completed

Review Details: GRADING

Permit Number - T05BU02233
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2005 ANDREW CONNOR NPPO REVIEW Denied 1. Site plan approval is necessary to continue review.

2. Additional comments may apply.
10/03/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: October 4th, 2005
ACTIVITY NUMBER: T05BU02233
PROJECT NAME: Materials Storage Yard
PROJECT ADDRESS: 1315 West Miracle Mile
PROJECT REVIEWER: Patricia Gilbert

The following items must be revised or added to the grading plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: GRADING PLAN

1. A copy of the stamped approved Site Plan must be included with the Grading Plan submittal.

2. Indicate building roof slope, downspouts and sidewalk scuppers. Add note, "All roof spouts will be routed under any adjacent sidewalk." Graphically indicate downspouts and sidewalk scuppers.

3. Indicate adjacent property zones.

4. Include a legend on the plan, indicating symbols and line weights used on the plan.

5. Indicate grade breaks. Indicate a grade break symbol in the legend.

6. Indicate area of disturbance and total area of site on the plan.

7. This site is over an acre is size and retention of stormwater is a requirement. Submit a drainage report addressing the retention requirements found in the Standards Manual for Drainage Design and Floodplain Management and in the Retention/Detention Manual.

8. Include on the site plan estimated fill quantities. If fill quantities equal zero, please note on the plan. DS 2-02.2.1.A.17.

9. Indicate basis of elevation and include the City Field Book and page number. DS 2-02.2.1.23.

10. Handicap curb access ramps are required to be constructed with truncated domes, per recent a Federal ADA requirement. Show a detail or add a general note to the site plan indicating all public and private handicap curb access ramps will have truncated domes.

11. Drainage patterns, proposed finish floor elevation(s), and finish grades. DS 2-02.2.1.A.16.

12. Show more spot elevations to determine direction of drainage. SD 2-02.2.1.A.23.

13. Indicate the dimensions for the trash enclosure (detail 3) on the inside of the enclosure. DS 6-01.

14. The stormwater pollution prevention plan is acceptable. Once the site plan and grading plan is approvable submit 4 copies of the stormwater pollution prevention plan.
10/09/2005 DAVID RIVERA ZONING REVIEW Denied 10/09/05

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/13/2005 JMORALE1 OUT TO CUSTOMER Completed
10/13/2005 SUE REEVES REJECT SHELF Completed