Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Permit Number - T05BU02114
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 11/28/2005 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | .. T05BU02114 .. 2537 N ORACLE ROAD .. RAMADA .. DGL .. 1ST REVIEW .. 11/29/05 .. S1. Clarify egress per IBC Section 1003 (level landings w/ sloped sidewalk). S2. Indicate occupant load on drawing A1 per IBC Section 1004. S3. Clarify code designations, as this is a commercial project IRC designations are not acceptable ref Frame Construction notes on drawing S1 (see IBC Section 23), current TPI-1 is 2002, for editions of Referenced Standards conforming to 2003 IBC, see 2003 IBC Chapter 35. S4. Show means of egress illumination per IBC Section 1006 (site lighting). S5. Show accessible means of egress per IBC Section 1007. S6. Designate accessible route on site plan per IBC Section 1104. S7. Show accessible parking on site plan per IBC Section 1106. S8. Provide stucco specifications and details, including flashing on drawing S1, per IBC Section 1405. S9. Clarify interior, is the interior finished ie: walls and ceiling, if so detail materials of construction and fastening to structure with corrosion resistant fasteners. S10. Provide roof covering specification and details per IBC Section 1507, including flashing. S11. Submit two sets of shop drawings and calculations, stamped and signed by an Arizona Registered engineer, shop drawings shall be reviewed by and bear the approval of the Engineer or Architect of Record prior to submission to the City of Tucson , Development Services Department for approval prior to erection for roof trusses. Questions? Call Douglas Laakso Structural Plans Examiner for the City of Tucson Development Services Department at (520) 791-5550 x1111. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/02/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 12/02/2005 | SUE REEVES | REJECT SHELF | Completed |