Permit Number: T05BU02084
Parcel: 11449042Q

Review Status: Completed

Review Details: GRADING

Permit Number - T05BU02084
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/30/2005 ANDREW CONNOR NPPO REVIEW Denied Site plan approval by all divisions is necessary to continue review.
09/12/2005 PAUL MACHADO ENGINEERING REVIEW Denied To: Bruce Wilson DATE: September 13, 2005
Landmark Engineering, Inc.
3845 N. Bussiness Center Drive
Tucson, Arizona 85718

SUBJECT: Sonic Restaurant, 2400 N. Pantano Rd.
Grading Plan T05BU02084 (First Review)
T13S, R15E, Section 33

RESUBMITTAL REQUIRED: Grading Plan, Drainage Statement.

The Grading Plan (GP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:
1. Please include a response letter to the comments along with the corrected copies of the GP.
2. The Grading plan cannot be approved prior to the approval of the Site Plan. Additional comments may be forth coming depending on the comments.
3. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. Call out truncated domes on the plan.
4. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting"
5. List the Grading plan number on the plans and also reference the Site plan number on the plans.
6. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed.
7. Show details of all surface materials.
8. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
9. Edit grading and paving note no. 6 to include D.S. 11.0.




Drainage Statement:
1. Please include a response letter to the comments along with the corrected copies of the DS.
2. A Drainage Statement is a brief description of drainage conditions applicable for a site which are not affected by 100 year flows of 100 cfs, of more……per S.M.D.D.F.M., chap. II, 2.1.2. The DS must be submitted along with the site plan and accepted with the approval of the grading plan.
3. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.2.
4. Show the project address or administration address on the cover sheet of the DS.
5. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DS.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/2400 N. Pantano Rd Grad
09/17/2005 DAVID RIVERA ZONING REVIEW Denied 09/17/05

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/22/2005 DELMA ROBEY OUT TO CUSTOMER Completed
09/22/2005 SUE REEVES REJECT SHELF Completed