Permit Number - T05BU01794
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/19/2005 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: September 19, 2005
ACTIVITY NUMBER: T05BU01794
PROJECT NAME: Thoroughbred Nissan
PROJECT ADDRESS: 5163 East 22nd Street
PROJECT REVIEWER: Patricia Gilbert

The following items must be revised or added to the grading plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: GRADING PLAN

1. The 8' foot wall located on the east perimeter of the site appears to be located within the future sight visibility triangle. It is not clear where the wall ends and begins. Clearly indicate where the wall is located in regards to the near side SVT (345'). Revise as necessary.

2. Keynote number 8 indicates a 390', 2' wide concrete valley gutter and refers to standard detail 208. The standard detail refers to concrete valley gutter that is 4' in width. Revise the note to indicate that the standard detail has been modified.

3. Submit three copies of the Grading plan and the Stormwater Pollution Prevention Plan with the next submittal.

4. Please note that if all the comments are addressed over the counter approval is possible. Please contact me to set up a time to meet, 791-5550, ext. 2206.
09/20/2005 ANDREW CONNOR NPPO REVIEW Denied Any screen or wall higher than thirty (30) inches must be located outside of the sight visibility triangle per LUC 3.7.3.4. Clarify the location of 8' masonry wall indicated on site and grading plans and if necessary remove any portion within sight visibility triangle.
10/04/2005 PETER MCLAUGHLIN ZONING REVIEW Denied Within sight-visibility triangles (SVTs), lines of sight may not be obscured between 30 inches and 6 feet in height. An eight-foot high screen wall appears to be located partially within the future near-side sight visibility triangle. Revise grading plan to demonstrate clearly that the wall is outside of SVT.