Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T05BU01702
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | DATE: July 22, 2005 TO: Danny Quihuis, ADG SUBJECT: Broadway/Harrison Retail Shell, 9485 E. Broadway Bl. Site and Grading Plan Review REVIEWER: Loren Makus, E.I.T. ACTIVITY NUMBERS: T05CM03335 and T05BU01702 SUMMARY: The Site Plan and Grading Plan were reviewed by Development Services Department Engineering Division and were not approved at this time. Revise the site and grading plans in accordance with the following comments. Site and Grading Plan comments: 1. DS 11-01.8.1.A Revise the site and grading plans so that no more than two feet of fill is to be placed in the north 100 feet of the project area unless all of the requirements of the Development Standard have been met. Either lower the proposed grades so that less than 2 feet of fill will be placed in this area or meet all the notification and mitigation requirements of the development standard. 2. The proposed grading plan indicates that there will be offsite grading. Provide a letter from the Department of Transportation indicating that the grading into the right of way is acceptable to the City and that it doesn't conflict with the referenced improvement plans. 3. DS 2-02.2.1.A.10 Show future sight visibility triangles for each driveway and for the intersection of Broadway Boulevard and Harrison Road. 4. Clarify Keynote 15 on Sheet S1.1. No basin appears to be proposed in the grading and paving plans. 5. Revise Grading and Paving Note 9 to indicate that all grading will comply with City of Tucson Development Standard 11-01. 6. Provide truncated dome warning surfaces for each area where sidewalks abut vehicle use areas with no vertical separation such as access ramps and depressed sidewalks. 7. Revise the detail for the solid waste enclosure on Sheet 1 of 1 to conform with the detail on Sheet 4 of 9 (Detail 8/3). Ten feet of clear space is required between the bollards along the sides of the solid waste enclosure. Revise the Site Plan and Grading Plan, to address all of these comments and resubmit two copies of the Site Plan Grading Plan. If you would like to meet with me to discuss any of these comments please call me at (520) 791-5550 ext. 1161 or email me at loren.makus@tucsonaz.gov. Loren Makus, E.I.T. Senior Engineering Associate Engineering Division Development Services |
| 07/20/2005 | JOE LINVILLE | NPPO | REVIEW | Denied | 1) Revise the grading plans to show the same right-of-way improvements as shown on the site plans. 2) Add a note to the grading plans stating: A pre-construction inspection for native plant preservation is required prior to any site disturbance. Call 791-5640 EXT. 1140 to schedule. |
| 08/04/2005 | DAN CASTRO | ZONING | REVIEW | Denied | Zoning Section may not approve the grading plan prior to Engineering approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/09/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 08/09/2005 | SUE REEVES | REJECT SHELF | Completed |