Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T05BU01511
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | DATE: June 29, 2005 SUBJECT: Rio Nuevo Mercado Borrow Plan submittal Grading Permit Engineering Review LOCATION: T14S R13E Section 14 REVIEWER: Elizabeth Eberbach ACTIVITY NUMBER: T05BU01511 SUMMARY: The Borrow Plan, and copies of the approved initial grading plan, were received by Engineering and has reviewed the received items, and does not recommend approval of this grading plan until the sewer comment is addressed. GRADING PLAN COMMENTS: 1) Regarding the sewer easement on sheet 3, the City has not received docket and page of the vacation of the 30' Public Utility and Sewer easement as requested at Tentative Plat stage. From discussions with consultant, there is an existing sewer line in this area and therefore grading near or on this easement is not accepted. Clarify intent of excavation, or revise area of borrow pit on this grading plan. 2) Add the following general notes: a) A copy of this borrow plan with grading permit, and geotechnical reports shall be kept at the site at all times, until final grading approval. b) Any revision to this grading plan MAY require a re-submittal of the revised grading plan for review. Contact DSD Engineering at 791-5550 to discuss changes in grading design. c) If grading construction is expected to last longer than the expiration date on the grading permit, contact DSD to renew or extend the grading permit. If the final grading inspection has not been completed before the grading permit expires, and the grading permit has not been renewed, additional fees and reviews may be required. d) Contact Permits and Codes (791-5100) for any right-of-way permit requirements. e) Call to see if a SWPPP inspection and Grading Pre-construction meeting will be required. For a DSD Engineering Inspections, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html or contact DSD Engineering at 791-5550 extension 2101. 3) On sheet 3, for the existing ingress/egress easement, delete "…to be vacated by separate instrument (dkt__ pg__)" if this is not to be vacated at this time during the grading excavation. 4) Assure any Environmental Services comments are addressed. Submit one copy of the previously approved onsite grading plans, one copy of the approve Tentative Plat, the four copies of the SWPPP, and 4 copies of the revised Borrow Plans. Questions, call me at 791-5550 ext.2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
| 07/08/2005 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 07/08/2005 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 07/13/2005 | DAVID BELL | LANDFILL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/20/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |