Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING
Permit Number - T05BU01167
Review Name: RESUBMITTAL - GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/28/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | Date July 30, 2005 SUBJECT: 3838 N. Campbell Grading Plan T05BU01167 (Second Review) T13S, R14E, Section 29 RESUBMITTAL REQUIRED: Grading Plan, Site Plan, Stormwater Pollution Prevention Plan, and Drainage Statement. The Grading Plan (GP), Stormwater Pollution Prevention Plan, and Drainage Statement cannot be approved as submitted. Please address the following review comments prior to the next submittal, and provide a detail response letter stating how each comment was address to assist in the follow up review process. Please submit a site plan, stormwate pollution prevention plan, and drainage statement in your next submittal. The grading plan will not be given the O.K. to submit without these items. General Comment: Please review red lines on the grading plans for additional comments and needed information. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies of the GP and drainage statement. 2. Provide Cross section at outlet of proposed storm water system. 3. Ensure that landscaping side slopes along walk path do not exceed a 4 to 1 slope. 4. Confirm that Pork Chop dimensions are to be reflected on Offsite improvement plans. If you have any questions, please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@tucsonaz.gov Jose E. Ortiz Civil Engineer City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1191 office (520) 879-8010 fax C:/0000 O. Street Address_Site |
| 07/28/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | DATE: July 29, 2005 ACTIVITY NUMBER: T05BU01167 PROJECT NAME: UMC Cancer Center PROJECT ADDRESS: 3838 North Campbell Avenue PROJECT REVIEWER: Patricia Gilbert, Engineering Associate APPROVED: STORM WATER POLLUTION PREVENTION PLAN RESUBMITTAL REQUIRED: 3 COPIES OF THE GRADING PLAN AND 3 COPIES OF THE STORM WATER POLLUTION PREVENTION PLAN. 1. Please note that SWPPP approval is contingent on approval of the grading plan. Once the grading plan has been approved the SWPPP will be approved. |
| 08/01/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | 1. Add note to grading plan or reference approved NPP plan pertaining to: All plants designated to be preserved-in-place shall be retained at their existing grade during and after construction. Preservation fencing per DS 2-06. Figure 1 is required to be installed beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A 2. Note on grading plan: Prior to any site disturbance a pre-grading inspection is required. Inspections may be scheduled by calling the IVR system at (520) 740-6970, inspection #9015 or by calling the Landscape Field Representative directly at 791-5640 Ext. 1140. |
| 08/02/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | 08/02/05 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved site/development plan. Additional comments may be forthcoming. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/03/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |