Review Details: GRADING

Permit Number - T05BU00583
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/01/2005 BLANCA ESPINO ENGINEERING REVIEW Denied 1. Please include a response letter with the next submittal that states how all comments have been addressed.

2. Indicate drainage patterns. Indicate adjacent finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16 It appears that the natural flow is being redirected to the south then to the west. Submit a drainage statement that demonstrates changed direction of flows. Indicate how onsite flows will not impact adjacent properties.

3. Filter fabric is required in rip-rap areas.

4. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20

5. Justify the purpose for the FFE to exceed two feet. Placement of fill in excess of two (2) feet or a finished floor elevation in excess of two feet plus the slab thickness above existing grade at any location in the outer one hundred feet of the developing site shall require:
· Written justification based on engineering/technical reasons.
· Written permission of the DSD/Eng or his/her assignee.
· Notification of the property owner(s) adjacent to the fill site with copies to the DSD/Eng prior to the approval of a grading plan.
Chapter 36.Sec 13.1
04/08/2005 ANDREW CONNOR NPPO REVIEW Denied Submit NPPO plan or application for exception per DS 2-15.0
04/21/2005 DAVID RIVERA ZONING REVIEW Denied 04/21/05

Development Services Department
Zoning Review Section

David Rivera
Senior Planner

Comments:

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering and Landscape Review Sections and zoning comments or concerns have been addressed.

2. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved site and landscape plans.

3. Two copies of the approved and stamped site plan, landscape and NPPO plans must be included with the grading plan.

Final Status