Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-COMMERCIAL
Permit Number - T05BU00571
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/10/2005 | MADARA ENGINEERING | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Completed | CITY OF TUCSON BUILDING SAFETY DEPARTMENT PERMIT APPLICATION PLAN CHECK COMMENT LIST 210 N. Stone Ave. Tucson, AZ 85701 Phone: (520) 791-4475 Fax: (520) 791-4475 Date: April 13, 2005 To: Tianay Stewart P. O. Box 91650 Tucson, AZ 85752 Phone: (520) 682-3160 Project name: 9250 E. Old Spanish Tr. Permit #: TO5BU00571 Structure: addition shade ramada Occupancy: U Construction Type: II-B Area: 2592 sq.ft. Project number: 18-5005-01 The first submittal plans for the above referenced project are in the process of Structural plan review for compliance with the City of Tucson ordinances and applicable codes. Corrections required are noted below. All corrections must be made to the original drawings and new complete and revised sets resubmitted along with a written response to each of the items listed below to facilitate a shorter back-check time. The scope of this review covers Structural review. These disciplines were checked only to the extent allowed by the documents provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. STRUCTURAL COMMENTS General Provide copy of approved ICC report number for the 30 Ga Powers “SB” metal deck used at roof diaphragm. Address design of roof diaphragm in structural calculations and justify lateral shear does not exceed allowable. Coordinate with structural calculations and resolve discrepancy in specifying lateral resisting system. Plans indicate Cantilever columns, where calculation pg.25 calls for shear walls shown on plans. Recheck uplift applicable at interior columns supporting high and low roof framing on pg.27 where tributary area shall be doubled and address resistance considering 06.D+W load combination as governing in this case. Recheck wind vertical pressure per IBC Tables 1609.2.1(1), 1609.6.2.1(3). Should you have any inquires regarding this letter, please do not hesitate to contact the Plan reviewer at (602) 493-1963. MADARA Engineering for the CITY OF TUCSON By: Mira Todorova, P.E. President |
05/10/2005 | MADARA ENGINEERING | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Approved | CITY OF TUCSON BUILDING SAFETY DEPARTMENT PERMIT APPLICATION PLAN CHECK COMMENT LIST 210 N. Stone Ave. Tucson, AZ 85701 Phone: (520) 791-4475 Fax: (520) 791-4475 Date: April 13, 2005 To: Tianay Stewart P. O. Box 91650 Tucson, AZ 85752 Phone: (520) 682-3160 Project name: 9250 E. Old Spanish Tr. Permit #: TO5BU00571 Structure: addition shade ramada Occupancy: U Construction Type: II-B Area: 2592 sq.ft. Project number: 18-5005-01 The first submittal plans for the above referenced project are in the process of Structural plan review for compliance with the City of Tucson ordinances and applicable codes. Corrections required are noted below. All corrections must be made to the original drawings and new complete and revised sets resubmitted along with a written response to each of the items listed below to facilitate a shorter back-check time. The scope of this review covers Structural review. These disciplines were checked only to the extent allowed by the documents provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. STRUCTURAL COMMENTS General Provide copy of approved ICC report number for the 30 Ga Powers “SB” metal deck used at roof diaphragm. Address design of roof diaphragm in structural calculations and justify lateral shear does not exceed allowable. Coordinate with structural calculations and resolve discrepancy in specifying lateral resisting system. Plans indicate Cantilever columns, where calculation pg.25 calls for shear walls shown on plans. Recheck uplift applicable at interior columns supporting high and low roof framing on pg.27 where tributary area shall be doubled and address resistance considering 06.D+W load combination as governing in this case. Recheck wind vertical pressure per IBC Tables 1609.2.1(1), 1609.6.2.1(3). Should you have any inquires regarding this letter, please do not hesitate to contact the Plan reviewer at (602) 493-1963. MADARA Engineering for the CITY OF TUCSON By: Mira Todorova, P.E. President |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/31/2005 | KMEDINA1 | OUT TO CUSTOMER | Completed |