Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T05BU00351
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/29/2005 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | |
| 07/30/2005 | DAN CASTRO | ZONING | REVIEW | Denied | Zoning may not approve the grading plan until the site plan has been approved by all sections and the grading plan has been approved by the Engineering Section. |
| 08/12/2005 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Approv-Cond | SUBJECT: Warehouse Revised Drainage Report, Site & Grading review DATE: 11AUG05 ACTIVITY NUMBERS: T05CM00691/T05BU00351 LOCATION: 1445 East Weiding Road, T15S, R14E, Section 7 Summary: Engineering Division has reviewed the resubmittal package. Conditional approval is recommended. Engineer was called and said he will make changes on the documents. Conditions of Grading Plan Approval: 1) Footing for retaining wall and building wall on the north side of the building adjacent to the retention basin shall be founded at least 5 feet below finished grade and be founded on a minimum depth of 3.0 feet of engineered fill. See geotechnical engineering addendum date May 2, 2005 by LMT Engineering, Inc. for further geotechnical recommendations. 2) Submit copies of geotechnical engineering inspections to DSD Engineering Division Inspector or office prior to scheduling Final Grading Inspection assuring that the footing for retaining wall and building wall on the north side of the building adjacent to the retention basin is founded at least 5 feet below finished grade and is founded on a minimum depth of 3.0 feet of engineered fill per LMT. 3) For the 6" by 6" tube steel drainline, use COT/PC Standard Detail 204. 4) All grading shall conform to Development Standards Section 11-01. 5) A copy of the Grading Plan, Grading Permit, and any Geotechnical Report with addenda shall be kept at the site at all times, until final grading approval. 6) Although the project is under 1 acre, interim stormwater pollution prevention control devices may be prudent to install during the monsoon season as determined by the contractor, project engineer, and/or inspector. 7) Any revision to the Grading Plan MAY require a re-submittal of a revised grading plan for review. Contact DSD Engineering at 791-5550 to discuss changes in grading design. 8) If grading construction is expected to last longer than the expiration date of the grading permit, contact DSD to renew/extend the Grading Permit. If Final Grading Inspection has not been completed before the Grading Permit expires, and the permit has not been renewed, additional fees and reviews may be required. 9) Call for Pre-construction meeting. For a DSD Engineering Inspection, call IVR (740-6970), or schedule with a Customer Service Representative at the Development Services Department, or contact DSD Engineering at 791-5550 extension 2101, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html For any questions, call me at 791-5550, extension 2204. Elizabeth Eberbach, PE Civil Engineer Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/24/2005 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 08/24/2005 | SUE REEVES | REJECT SHELF | Completed |