Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T05BU00288
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/24/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Robert T. Dermer DATE: February 25, 2005 General Contractor 980 S. McKinley Tucson, Arizona 85711 SUBJECT: 9616 E. Quail Place Grading Plan T05BU00288 (First Review) T14S, R15E, Section 14 RESUBMITTAL REQUIRED: Grading Plan and Drainage Statement The Grading Plan (GP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Grading plan clearly marked "GRADING PLAN". 2. Include a response letter to the comments along with the corrected copies of the GP. 3. A site with grading (fill) in excess of 50 cu.yds. reqiures a Grading Plan. 4. Call out on the plan view where the retaining wall will be used and refer to the retaining wall detail. 5. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting" 6. Show the slope between the new house and South property line. 7. Show all symbols in the legend. The limits of grading are difficult distinguish. A heavier line would be sufficient. 8. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 9. Provide additional Dainage patterns and finished grades per D.S. 2-02.2.1.16. There is not sufficient vertical information on the plans to determine code compliance. 10. Cut or fill slopes require a 2' minimum setback from property line. 11. List all Cut and Fill quantities in cubic yards. If both are 0 cy, please list. 12. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 13. Call out all slopes and stabilization material (concrete, riprap, gabbions or vegetation). 14. Slopes of 3H: 1V require hand placed riprap. 15. Slopes of 2H: 1V or greater require grouted riprap. 16. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address. 17. Drainage patterns with percent slopes (Show patterns within the first 100 feet from the property line). 18. Flow arrows, grades and flow rates within and adjacent to site to show drainage scheme. Drainage Statement: 1. A Drainage Statement is required. A DS is a brief description of drainage conditions applicable for a site which is not affected by 100-year flows of 100 cfs or more………. S.M.D.D.F.M., Chap. II, 2.1.3. 2. The content and format of the DS should follow S.M.D.D.F.M., chap. II, 2.3.1. 3. Show the project address on the cover of the DS. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/9616 E. Quail Place Grad |
| 03/07/2005 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 03/19/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | 03/19/05 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: Approved site plan must be included with the grading plan. Zoning cannot approve the grading plan until both Engineering and Landscape reviewers have approved the plan. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/29/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |