Permit Review Detail
Review Status: Completed
Review Details: WALLS
Permit Number - T05BU00177
Review Name: WALLS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/09/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | 03/19/05 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. Submit approved and stamped site plan. witht eh next submittal. The site plan as drawn does not depict exisitng conditions as depicted in the 2002 aerial. Please revise the site plan to correctly depict exisitng conditions on both properties or submit approved site plan. 2. The site plan must include all easements as depicted on the plat, M/P 34/07. |
| 02/09/2005 | NEAL SAUNDERS | BUILDING-RESIDENTIAL | REVIEW | Denied | To: Robert T. Dermer DATE: February 25, 2005 General Contractor 980 S. McKinley Tucson, Arizona 85711 SUBJECT: 9616 E. Quail Place Site Plan T05BU00177 (First Review) T14S, R15E, Section 14 RESUBMITTAL REQUIRED: Site Plan and Drainage Statement The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the SP. 2. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 3. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 4. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 5. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 6. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. 7. Show Site plan number (TO5BU00177) on all sheets per D.S. 2-02.2.1.29. 8. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address. 9. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 10. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Drainage Statement: 1. A Drainage Statement is required. A DS is a brief description of drainage conditions applicable for a site which is not affected by 100-year flows of 100 cfs or more………. S.M.D.D.F.M., Chap. II, 2.1.3. 2. The content and format of the DS should follow S.M.D.D.F.M., chap. II, 2.3.1. 3. Show the project address on the cover of the DS. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/9616 E. Quail Place Site |
| 03/22/2005 | SREEVES1 | NPPO | REVIEW | Needs Review | |
| 03/22/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | To: Robert T. Dermer DATE: February 25, 2005 General Contractor 980 S. McKinley Tucson, Arizona 85711 SUBJECT: 9616 E. Quail Place Grading Plan T05BU00288 (First Review) Wall Permit T05BU00177 (First Review) T14S, R15E, Section 14 RESUBMITTAL REQUIRED: Grading Plan and Drainage Statement The Grading Plan (GP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Grading plan clearly marked "GRADING PLAN". 2. Include a response letter to the comments along with the corrected copies of the GP. 3. A site with grading (fill) in excess of 50 cu.yds. reqiures a Grading Plan. 4. Call out on the plan view where the retaining wall will be used and refer to the retaining wall detail. 5. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting" 6. Show the slope between the new house and South property line. 7. Show all symbols in the legend. The limits of grading are difficult distinguish. A heavier line would be sufficient. 8. All easement of record must be graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 9. Provide additional Dainage patterns and finished grades per D.S. 2-02.2.1.16. There is not sufficient vertical information on the plans to determine code compliance. 10. Cut or fill slopes require a 2' minimum setback from property line. 11. List all Cut and Fill quantities in cubic yards. If both are 0 cy, please list. 12. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 13. Call out all slopes and stabilization material (concrete, riprap, gabbions or vegetation). 14. Slopes of 3H: 1V require hand placed riprap. 15. Slopes of 2H: 1V or greater require grouted riprap. 16. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address. 17. Drainage patterns with percent slopes (Show patterns within the first 100 feet from the property line). 18. Flow arrows, grades and flow rates within and adjacent to site to show drainage scheme. Drainage Statement: 1. A Drainage Statement is required. A DS is a brief description of drainage conditions applicable for a site which is not affected by 100-year flows of 100 cfs or more………. S.M.D.D.F.M., Chap. II, 2.1.3. 2. The content and format of the DS should follow S.M.D.D.F.M., chap. II, 2.3.1. 3. Show the project address on the cover of the DS. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/9616 E. Quail Place Grad |